City of Douglas (AZ)

Arizona Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2005
Fire Code Version2018 Building Code
Wet Stamps RequiredNone
Fire Setback Enforced1

Codes

NEC Code Version
2005
Fire Code Version
2018 Building Code
Code List

2006 INTERNATIONAL BUILDING CODE

2006 INTERNATIONAL RESIDENTIAL CODE

2005 NATIONAL ELECTRICAL CODE

2006 INTERNATIONAL CODE COUNCIL ELECTRICAL CODE

2006 INTERNATIONAL PLUMBING CODE

2006 INTERNATIONAL FUEL GAS CODE

2006 INTERNATIONAL MECHANICAL CODE

2006 INTERNATIONAL EXISTING BUILDING CODE

2006 INTERNATIONAL ENERGY CONSERVATION CODE

ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

How Many Plansets Required
3
Revision Required
0
New Planset Required For Module Swap
0

Stamps

Ee Stamp Required On SLD
No
Wet Stamps Required
None
Structural Calculations Required
No

Fire setbacks

Fire Setback Enforced
1
Setback Notes

Standard

Structural & loads

Wind Speed
115
Wind Notes

Exposure Category B

Snow Load
5
Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Structural Notes
Marking no structural needed based on this job will update once we receive the feedback: (a past project Del Mar- 502 N Elizabeth ave) 1/26/2021 - BC
Minimum Ground On Roof
#10

Electrical

Electrical Load Calcs Required
Derates
Allowed POI
Line Side Taps,PV Breaker,Meter Adapter,Load Side Taps
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
0.91

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes

Standard

Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Plan set

Plan Set Requirements

Below are a few APS requirements that Miguel has mentioned for Douglas jobs: All solar jobs will need a minimum 200A service 3ft clearance from windows and doors Equipment can't be below or above windows They would like the equipment towards the front of the house, preferably on the side but if that doesn't work it can be on the front of the house. Provide elevation drawings from front, sides and rear as well that would represent the visual of the array panels as proposed for mounting

Electrical Diagram

Standard

Custom Placards Required
0
Non Standard Planset Requirements
BOS Elevation

Ground mount

Ground Mount Fencing Required
Mesh/Scrim
Compiled from public records, 2026. Requirements change with code cycles and local amendments. Verify with the City of Douglas (AZ) building department before you rely on this, and treat it as a research head start, not a ruling. Getting quotes? Run them through the quote checker first.