City of Litchfield Park (AZ)
Codes
- NEC Code Version
- 2017
- Fire Code Version
- 2018 Building Code
- Code List
2012 INTERNATIONAL BUILDING CODE 2012 INTERNATIONAL RESIDENTIAL CODE 2012 INTERNATIONAL PLUMBING CODE 2012 INTERNATIONAL MECHANICAL CODE 2005 NATIONAL ELECTRIC CODE 2012 INTERNATIONAL FUEL GAS CODE 2012 INTERNATIONAL FIRE CODE 2012 INTERNATIONAL ENERGY CONSERVATION CODE ADA- ICC/ANSI A117.1-2003
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 2
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
* Fire Access Pathways identified and reference section 605.11.3 IFC (1 street side, and 1 on another roof plane - not blocking residential egress)
Structural & loads
- Wind Speed
- 90
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Snow Load Notes
Ground Snow Load: 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Meter Adapter,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.87
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
PRE-FILLED SOLAR PERMITS CHECKLIST ATTACHED BELOW LINE-SIDE TAP MAY NOT BE ALLOWED, AHJ CONFIRMATION REQUIRED
- Roof Plan
* Fire Access Pathways identified and reference section 605.11.3 IFC (1 street side, and 1 on another roof plane - not blocking residential egress)
- Electrical Diagram
* SLD and TLD pages required * indicate phase and voltage of MSP on SLD & TLD
- Non Standard Planset Requirements
- Single Line Diagram
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Ground Mount Notes
Shall be located in a rear yard and need to be placed at least five (5) feet from the rear or side property lines. Shall be fully screened from public view by a surrounding yard wall. Fence or mesh okay as long as the GM is not "readily accessible" If using a fence, it can't be more than 6ft high. Ground screws allowed with engineering. No freeze-thaw minimum depth. No gravel base required. If within a floodplain, the GM must be protected from soil erosion. Depending on where in the floodplain, the AHJ may require it to be placed at or above flood elevation.
- Setback Side Yard
- 5