City of Scottsdale (AZ)

Arizona Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2020
Fire Code Version2018 Building Code
SolarAPP+ StatusTargeted
Wet Stamps RequiredNone
Fire Setback Enforced1

Codes

NEC Code Version
2020
Fire Code Version
2018 Building Code
Code List

2021 International Building Code

2021 International Residential Code

2021 International Mechanical Code

2021 International Plumbing Code

2021 International Energy Conservation Code

2021 International Green Construction Code

2021 International Fuel Gas Code

2021 International Existing Building Code

2021 International Fire Code

2021 International Code Council

2010 Americans with Disabilities Act

2021 International Code Council

2020 National Electric Code

ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

SolarAPP+ Status
Targeted
Any SolarAPP+ Restrictions
1
SolarAPP+ Restrictions
Existing Systems,Trenching,Derate
How Many Plansets Required
3
Revision Required
1
Rough Inspection
None
New Planset Required For Module Swap
0

Stamps

Ee Stamp Required On SLD
Yes
Wet Stamps Required
None
Structural Calculations Required
No
Stamp Location On Plans
Unspecified
Date On Stamps
Expiration Date

Fire setbacks

Fire Setback Enforced
1
Setback Notes

Standard

Structural & loads

Wind Speed
115
Wind Notes

Exposure Category B

Snow Load
0
Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Structural Notes
Arrays with dead loads exceeding 50 lbs. at mounting points, shall require structural analysis. Ballasted systems will require a site visit by the engineer.
Minimum Ground On Roof
#8

Electrical

Electrical Load Calcs Required
Derates
Allowed POI
Load Side Taps,PV Breaker,Meter Adapter,Line Side Taps
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
0.82

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes

Per NEC 408.4(aq) Every circuit and circuit modification shall be legibly identified as to its clear evident and specific purpose or use. Each circuit shall have distinct name.

Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Plan set

Roof Plan

flat roofs the panels cannot be more than 30" off of the roof. with or without parapet walls.

Attachment Detail Notes

All Jobs [Panels shall not exceed 8" above sloped or 30" above flat roof surface. Panels to be parallel with the pitch of the roof Placement of panels shall be uniform Color of panel frames and hardware shall be non-reflective and be compatible with the roof surface. Panels shall not project above adjacent roof ridge line Panel glass shall incorporate anti-glare or anti-reflective surface]

Electrical Diagram

Centerfed 120%: EE Stamp Required Provide Fault studies, Busbar load calculations, & AZ EE Stamp FPE - auto MPU Old Zinsco panels - case by case. Provide load calculations and historical peak demand from utility company to justify derate. String wire size _must_ consider derate (.82) and conduit fill derate. (Wire size x derate x conduit fill derate = ampacity.) Total amps divided by the number of strings must be less than the maximum conductor rating. ( Example: On a 3 string system, generally upsize to #8 wire from junction box to inverter. 40A x temp derate of 0.80 x conduit fill 0.58 = 18.56A max conductor rating. 18.56A is less than 19.79A [47.5As / 3 strings * 1.25] total amps per string. ) A surge protector device is required when upgrading the service.

Custom Placards Required
0

Ground mount

Ground Mount Fencing Required
Mesh/Scrim