County of Cochise (AZ)
NEC Code Version2014
Fire Code Version2018 Building Code
Wet Stamps RequiredNone
Fire Setback Enforced1
Codes
- NEC Code Version
- 2014
- Fire Code Version
- 2018 Building Code
- Code List
2015 INTERNATIONAL BUILDING CODE
2015 INTERNATIONAL FIRE CODE
2012 INTERNATIONAL RESIDENTIAL CODE
2014 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- None
- Structural Calculations Required
- No
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 90
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
- Site plan must include driveway, property dimensions, setbacks from property lines, gates, fences, septic and leach fields, and any other existing buildings or features on the property. [Mackenzie-a past project. DCR 062121] No 3rd party PE requirements.
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,Meter Adapter,PV Breaker,Load Side Taps
- Panel Schedule Required
- All Projects
- Temperature Rating
- 90
- De Rating Ampacity
- 0.87
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
- PM not required.
- No published information about battery placement.
- Wire size from Battery disconnect to Battery meter must be 8-AWG.
- Conduit schedule must show (4) 8-AWG wires.
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Site
Site plan must include
- Driveway
- Property dimensions
- Setbacks from property lines
- Gates
- Fences
- Septic and leach fields
- Any other existing buildings or features on the property.
- Reference: Mackenzie-a past project. DCR 062121
Note:
Although the land is owned by the same property owner, most structures have separate parcel numbers. Please click the link to confirm the parcel number is correct: Cochise County Open Data (arcgis.com).
- Electrical Diagram
Line side taps require additional approval from the utility company, which may extend timelines for the customer.
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes
- Setback Side Yard
- 10