County of Gila (AZ)
Codes
- NEC Code Version
- 2011
- Fire Code Version
- 2018 Building Code
- Code List
2012 INTERNATIONAL RESIDENTIAL CODE 2012 INTERNATIONAL BUILDING CODE 2012 INTERNATIONAL EXISTING BUILDING CODE 2012 INTERNATIONAL FUEL GAS CODE 2012 INTERNATIONAL MECHANICAL CODE 2012 INTERNATIONAL PLUMBING CODE 2012 UNIFORM SWIMMING POOL, SPA & HOT TUB CODE 2011 NATIONAL ELECTRIC CODE ICC A117.1-2009 ACCESSIBLE AND USUABLE BUILDINGS AND FACILITIES CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 2
- Revision Required
- 1
- Rough Inspection
- Racking Inspection
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 999
- Snow Load Notes
Below 4500 ft elevation - 20 PSF roof, 28 PSF Ground Between 4500 - 6000 ft elevation - 40 PSF roof, 57 PSF Ground Above 6000 ft elevation - 40 PSF Roof, 57 PSF ground (See _Gila County Design Criteria_ Document below)
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Structural Calcs required on all projects. Need to show both _**ground** and **roof snow**_ loads on both _ **Plans** and **Calcs**_ When sending to engineer, inlcude the file named _Gila County Design Criteria_ in file section below.
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,PV Breaker,Meter Adapter,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
NEED GROUND AND ROOF SNOW LOADS ON BOTH PLANS AND STRUCTURAL CALCS OR PLANS WILL BE REJECTED AT TIME OF SUBMITTAL Need live roof snow load AND ground snow load. System with batteries and/or generator: Cut sheet for batteries. 2 copies (Battery conductors must be NEC approved) Cut sheet for battery storage container or racking if applicable. 2 copies Cut sheet and listing for battery charge controller. 2 copies Cut sheet (2 copies) and installation manual (1 copy) for generator and transfer switch. Roof mounted system: (dc ground fault protection required) Signed waiver for installation on an existing building. For new manufactured homes, the Office of Manufactured Housing requires the home's manufacturer be contacted to determine if and how modules may be installed. Provide manufacturer's approval. Roof framing information (mfg trusses, rafter sizes & spacing). Contact office for specific requirements if installation is to be on an existing manufactured home. Weight of array with mounting system in psf and point loads (structural engineering may be required due to excessive psf and/or point loads or if other unique circumstances deem it necessary) Approximate age of building and roofing type (asphalt shingle, clay tile, metal) Installation manual (1 copy) or engineered detail (2 copies) of module support attachment to roof framing members and method of sealing roof penetrations. MODULE SUPPORT/RACKING AND SUPPORT BONDING/GROUNDING
- Site
Include the following on site plan: • North Arrow • Parcel # and Address • Street names • Dimensioned lot lines • Setback lines with dimensions to property lines • Locations and dimensions of all existing and proposed structures (include fences) and distances between structures and lot lines • Locations of all washes, ditches, creeks and drainages. • All easements, driveways • Septic systems and leach fields • Locations of all existing and proposed utilities including: o Utility lines and underground piping o Water, electric, and gas meters o Well o Propane tank and distances to property lines and any structures
- Electrical Diagram
Standard
- Label Page
Map placard must be added to page
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Ground Mount Notes
Ground mounted system: ⌂ Weight of array in psf and point loads including mounting system. ⌂ Detail of engineered or manufacturer’s array support, framing members, foundation posts and footings. 2 copies (footings must meet frost depth requirement) ⌂ Array height above grade noted on plans. ⌂ Energized parts operating at 50 volts or more shall be guarded against accidental contact by approved enclosures.