County of Pinal (AZ)
Codes
- NEC Code Version
- 2017
- Fire Code Version
- 2018 Building Code
- Code List
2018 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL RESIDENTIAL CODE
2018 INTERNATIONAL MECHANICAL CODE
2018 INTERNATIONAL PLUMBING CODE
2018 UNIFORM PLUMBING CODE
2018 INTERNATIONAL FUEL GAS CODE
2018 INTERNATIONAL ENERGY CONSERVATION CODE
2018 INTERNATIONAL EXISTING BUILDING CODE
2018 INTERNATIONAL SWIMMING POOL AND SPA CODE
2018 INTERNATIONAL FIRE CODE
2017 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 2
- Revision Required
- 1
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- No
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category C
- Snow Load
- 0
- Snow Load Notes
Pinal County does not require a snow load
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Manufactured/Mobile Homes: Require structural stamps and calcs
All other projects: Stamps are not a requirement
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Meter Adapter,PV Breaker,Load Side Taps,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
- BOS Restrictions
Mobile Homes: BOS cannot be placed on the home
Battery / ESS
- Unique Battery Placards Needed
- 1
- ESS Notes
- Separate ESS Disconnect Required
- Gateway Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
- Roof Plan
Show all fire setbacks, pathways, and dimensions
- Attachment Detail
- Attachment Detail Notes
ALL JOBS
- INCLUDE DIMENSION FROM TOP OF ROOF TO TOP OF THE SOLAR PANEL ON ATTACHMENT DETAIL.
- INCLUDE LEADER POINTING TO DIMENSION STATING "DISTANCE FROM TOP OF ROOF TO TOP OF PANEL."
- Electrical Diagram
ALL JOBS
- SINGLE AND 3 LINE DIAGRAM REQUIRED
- INCLUDE SPECS FOR MPU
- Custom Placards Required
- 0
- Non Standard Planset Requirements
- Single Line Diagram
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes
GROUND MOUNTED SOLAR THE SITEPLAN NEEDS TO BE ONE PAGE ONLY (FOR ZONING)
60' from front
4' from back and sides unless it's on a corner lot then it is 20' unless easement is worked in then it will be an additional 33' to the 20'.
10' from septic.
5' from existing structures (barn, shed, NOT HOUSE)
7' from house including PORCH
Soil Class: Gravel
- Setback Front Yard
- 60
- Setback Back Yard
- 4
- Setback Side Yard
- 4