Town of Marana (AZ)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2024 INTERNATIONAL BUILDING CODE
2024 INTERNATIONAL EXISTING BUILDING CODE
2024 INTERNATIONAL PLUMBING CODE
2024 INTERNATIONAL RESIDENTIAL CODE
2024 INTERNATIONAL MECHANICAL CODE
2024 INTERNATIONAL PROPERTY MAINTENANCE CODE
2024 INTERNATIONAL ENERGY CONSERVATION CODE
2024 INTERNATIONAL FIRE CODE
2024 INTERNATIONAL FUEL GAS CODE
2024 INTERNATIONAL SWIMMING POOL AND SPA CODE
2024 TOWN OF MARANA OUTDOOR LIGHTING CODE
2023 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 1
- Revision Required
- 1
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- None
- Structural Calculations Required
- No
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
- Structural calcs required by Registered Engineer when the following weight loads are exceeded: - Distribution weight load - 4 pounds per square foot and/or Point load per attachment - 40 pounds -
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates,Load Relocation
- Allowed POI
- Meter Adapter,PV Breaker,Load Side Taps,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
PM required. Call out MILBANK U4518-XL-W. If DC Disco required, use SQUARE D HU361RB. Inv > PM > Utility DG Disconnect > POI No published information about battery placement.
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Structural calcs required by Registered Engineer when the following weight loads are exceeded: - Distribution weight load - 4 pounds per square foot and/or Point load per attachment - 40 pounds Exterior elevation(s) as necessary to show the proposed solar panels (attachment detail should be sufficient)
Provide a minimum 3.25 wide x 1.25 high clear space, near the title block on all pages for application of the approval stamp
- Site
Show all existing structures
- Electrical Diagram
When electrical load calcs are required, include any existing pool equipment as applicable to the project. Must include fault calc and statement letter from EE, as well as stamped load calcs
- Custom Placards Required
- 0
- Non Standard Revision Requirements
Only red cloud revisions requested by the AHJ. The AHJ does not want any other changes red clouded.
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Ground Mount Notes
Ground Mounts do not require site-specific engineering unless shade structure or > 6' height
- Setback Side Yard
- 5