City of La Canada Flintridge (CA)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2025 CALIFORNIA BUILDING CODE
2025 CALIFORNIA ELECTRICAL CODE
2025 CALIFORNIA FIRE CODE
2025 CALIFORNIA PLUMBING CODE
2025 CALIFORNIA MECHANICAL CODE
2025 CALIFORNIA ENERGY CODE
2025 CALIFORNIA RESIDENTIAL CODE
2025 CALIFORNIA ADMINISTRATIVE CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Adopted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- Existing Systems,Trenching
- How Many Plansets Required
- 1
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes - Tile Roof
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 110
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,PV Breaker,Meter Adapter,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
- BOS Restrictions
Standard
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
[LACOF]
This AHJ follows County of Los Angeles (ESS Requirements) (CA).
Please follow this link to County of Los Angeles (ESS Requirements) (CA)
ESS disconnect required within 6ft of MSP on same wall and not blocked by walls/gates/etc
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- Yes - with dimensions
Plan set
- Plan Set Requirements
2017 Los Angeles codes, elevation page on plans is required for zoning approval. See requirements for plans attachment Testing AHJ requirements with: a past project Informational note (pending confirmation of new code adoption) The City has adopted by reference, with certain exceptions, the 2017 Los Angeles County Building and 2017 Los Angeles County Fire codes. These codes are modified from the basic statewide 2016 California Building and Fire Codes. The augmented codes to be adopted are: Title 26 Building (https://library.municode.com/ca/los_angeles_county/codes/code_of_ordinances?nodeld=TIT26BUCO) Title 27 Electrical (https://docs.google.com/a/lcf.ca.gov/viewer?a=https://library.municode.com/ca/los_angeles_county/codes/code_of_ordinances?nodeld=TIT27ELCO) Title 28 Plumbing (https://library.municode.com/ca/los_angeles_county/codes/code_of_ordinances?nodeld=TIT28PLCO) Title 29 Mechanical (https://library.municode.com/ca/los_angeles_county/codes/code_of_ordinances?nodeld=TIT29MECO) Title 30 Residential (https://library.municode.com/ca/los_angeles_county/codes/code_of_ordinances?nodeld=TIT30RECO) Plans require an elevation page. Please look at PDF with requirements
- Electrical Diagram
Standard
ENPHASE ESS:
Add note to the single line diagram: βAt the IQ System Controller 3, remove the bonding jumper wire.β
- Custom Placards Required
- 1
- Non Standard Planset Requirements
- BOS Elevation
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim