City of Lancaster (CA)

California Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2023
Fire Code Version2018 Building Code
SolarAPP+ StatusTargeted
Wet Stamps RequiredDigital Structural
Fire Setback Enforced1

Codes

NEC Code Version
2023
Fire Code Version
2018 Building Code
Code List

2025 CALIFORNIA BUILDING CODE

2025 CALIFORNIA ELECTRICAL CODE

2025 CALIFORNIA FIRE CODE

2025 CALIFORNIA PLUMBING CODE

2025 CALIFORNIA MECHANICAL CODE

2025 CALIFORNIA ENERGY CODE

2025 CALIFORNIA RESIDENTIAL CODE

2025 CALIFORNIA ADMINISTRATIVE CODE

ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

SolarAPP+ Status
Targeted
Any SolarAPP+ Restrictions
1
SolarAPP+ Restrictions
MPU,Derate
How Many Plansets Required
1
Revision Required
1
Rough Inspection
None
New Planset Required For Module Swap
1

Stamps

Wet Stamps Required
Digital Structural
Structural Calculations Required
Yes
Stamp Location On Plans
Top Right
Date On Stamps
Date Plans are Stamped

Fire setbacks

Fire Setback Enforced
1
Setback Notes

Standard

Structural & loads

Wind Speed
110
Wind Notes

Exposure Category B

Snow Load
20
Snow Load Notes

N/A

Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Structural Notes
  • Batteries will require structural calculations to certify the mounting of the battery on the wall.
Minimum Ground On Roof
#10

Electrical

AC Disconnect Required
Yes
AC Disconnect Conditional Criteria
All power feeding the house needs to be able to be shut down within 6’ of main service panel
Electrical Load Calcs Required
Derates
Allowed POI
PV Breaker,Meter Adapter,Load Side Taps,Line Side Taps
Panel Schedule Required
Whole Home Backup
Temperature Rating
90
De Rating Ampacity
0.91
BOS Restrictions

AC disconnect must be on same side of fence as MSP

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes
  • This AHJ follows County of Los Angeles (ESS Requirements) (CA).
  • Please follow this link to County of Los Angeles (ESS Requirements) (CA)
  • IF USING A SUB FEED LUG KIT, VERIFY THE LUG KIT TYPE ON THE TLD (Manufacturer provided kit for the bus bar, breaker style lug connection, etc.)
  • ALL Disconnects need to be located within 6’ of the main service panel
  • Bollards are required if ESS is/are installed under 3' high in a driveway.
  • WALL MOUNTED BATTERIES REQUIRE STRUCTURAL ENGINEERING ON BATTERY LOCATION / ATTACHMENT
  • Provide calculation analysis for the ESS gravity and lateral out-of-plane support. Connection at top and bottom of stud maybe required to resist out-of-plane forces unless otherwise justified, not required. Number of fasteners, type, diameter, embedment, hardware brackets, etc. shall be clearly illustrated in detail.
Separate ESS Disconnect Required
Local Disconnect,ESS Disconnect
ESS Elevation Detail Required
Yes - with dimensions

Plan set

Plan Set Requirements
  •  Please provide an equipment elevation with building disconnects identified and a corresponding disconnect schedule. 
  • All required means of disconnect must be located within 6 feet of the main service panel, on the same wall plane, and not separated from one another by walls, gates, fences, vegetation, or architectural features of the building.
Site
  • The layout of existing PV systems must be illustrated as individual modules, not as a single “obstruction.”
  • Module layouts must be replicated in Aurora before downloading the DXF.
Attachment Detail

All Jobs [DOUBLE FLASHING IS REQUIRED FOR THIS AHJ]

Electrical Diagram

Existing Systems:

  • Existing system and new system must be combined to have one POI in the MSP per CEC 705.12(3)(2).
Electrical Diagram Notes

All Jobs [PER CEC 705.12(3)(2) THE BACKFEED BREAKER SHALL BE INSTALLED AT THE OPPOSITE END OF THE BUS BAR FROM THE MAIN OCPD]

Custom Placards Required
1
Placards Notes

Permanent placards in compliance with LA County Fire regulations + all permanent placards from placard page of plan set.

Non Standard Planset Requirements
BOS Elevation

Ground mount

Ground Mount Fencing Required
Yes
Ground Mount Notes
  • Ground mount: Fence must be 6-8 ft tall.
  • Nuance systems are not permitted; always design using IronRidge.
  • Only NRTL-listed systems are allowed in the City of Lancaster.
  • If the system is not NRTL-listed, provide compliant documentation or revise the design to use traditional posts embedded in concrete footings.
Compiled from public records, 2026. Requirements change with code cycles and local amendments. Verify with the City of Lancaster (CA) building department before you rely on this, and treat it as a research head start, not a ruling. Getting quotes? Run them through the quote checker first.