City of Lynwood (CA)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2025 CALIFORNIA BUILDING CODE
2025 CALIFORNIA ELECTRICAL CODE
2025 CALIFORNIA FIRE CODE
2025 CALIFORNIA PLUMBING CODE
2025 CALIFORNIA MECHANICAL CODE
2025 CALIFORNIA ENERGY CODE
2025 CALIFORNIA RESIDENTIAL CODE
2025 CALIFORNIA ADMINISTRATIVE CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Adopted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- Existing Systems,Trenching
- How Many Plansets Required
- 3
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- None
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Fire access pathways shall be 3 ft in addition to the length of the overhang. (If overhang is 1 ft, total setback would be 4 ft) Pathways must be over supported roof structure meaning setbacks start at a load bearing wall
Structural & loads
- Wind Speed
- 130
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Snow Load Notes
N/A
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
WS: 130mph. Exposure B.
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,PV Breaker,Meter Adapter,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 1
- BOS Restrictions
Standard
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
This AHJ requires County of LA ESS requirements
- Please follow this link to County of Los Angeles (ESS Requirements) (CA)
- add rapid shutdown device to disconnect schedule
ESS disconnect required within 6ft of MSP on same wall and not blocked by walls/gates/etc
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- Yes - with dimensions
Plan set
- Site
- Site Notes
- Do not cover mechanical and plumbing vents on the roof with solar PV panels.
- No active fire sprinkler.
- A roof access point should be provided that does not place a ground ladder over an opening such as a window or door. Located at a solid point in the building construction and in the locations where the access point does not conflict with overhead obstructions such as tree limbs, wires, or signs.
- Notify serving utility before activation of PV system.
- Roof Plan
- Do not cover mechanical and plumbing vents on the roof with solar PV panels.
- No active fire sprinkler.
- A roof access point should be provided that does not place a ground ladder over an opening such as a window or door. Located at a solid point in the building construction and in the locations where the access point does not conflict with overhead obstructions such as tree limbs, wires, or signs.
- Notify serving utility before activation of PV system.
- Attachment Detail
Structural plans and calculations shall be signed by a licensed civil engineer showing supporting member sizes, dimensions, materials and loads imposed on the roof structure are adequate, unless all of the following conditions are met:
The existing roofing is either of wood shingle, asphalt shingle, or rolled/torch-down with two layers maximum.
The solar PV system weighs not more than 4 psf.
The maximum allowable concentrated load imposed by a solar PV system support onto the roof structure is 40 lbs.
The solar PV panels are installed with no portion thereof more than 18 inches above the roof immediately below.
Maximum spacing for supports of the solar PV system on wood-framed construction shall be 48 in. on center and shall be anchored to roof rafters or to solid blocking with a minimum of one 5/16 in. diameter lag screw embedded a minimum of 2 1/2 in. or as recommended by the manufacturer, whichever is more stringent.
- Electrical Diagram
120% rule allowed per CEC 705.12(B)(2)(3)(d)
- Custom Placards Required
- 1
- Placards Notes
Standard CA permanent placard requirement
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim