City of Millbrae (CA)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2025 CALIFORNIA BUILDING CODE
2025 CALIFORNIA ELECTRICAL CODE
2025 CALIFORNIA FIRE CODE
2025 CALIFORNIA PLUMBING CODE
2025 CALIFORNIA MECHANICAL CODE
2025 CALIFORNIA ENERGY CODE
2025 CALIFORNIA RESIDENTIAL CODE
2025 CALIFORNIA ADMINISTRATIVE CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 110
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
- Minimum Ground On Roof
- #10
Electrical
- AC Disconnect Required
- Yes
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,PV Breaker,Line Side Taps,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 1
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Follow manufacture installation requirements
If ESS is installed inside of garage, 1207.11.6 states that a smoke alarm or heat alarm shall be installed in the vicinity of the battery system. As such, please address each of the following:
- Please also note on the plans that the new alarm must be interconnected with the smoke alarm in the home (per the alarm’s installation instructions).
- In addition, please provide the model number and information sheet about such detector/alarm.
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
All plans shall be submitted in black and white only, colored plans will not be accepted as color is reserved for Building Division staff markups.
- Site Notes
Property must comply with the City of Millbrae front yard landscaping requirement (Municipal code section 10.05.0620(G)(2)). Please provide a note on a site plan if the property complies with the front yard landscaping requirement. If the property is currently not compliant, modifications to the site must be made to comply with the requirement prior to the final inspection and sign-off of the permit
For ESS installed in garage:
1207.11.6 states that a smoke alarm or heat alarm shall be installed in the vicinity of the battery system. As such, please address each of the following:
- Please update the plans to show a smoke alarm (or heat alarm in areas where a smoke alarm cannot be installed based on their listing) in the attached garage.
- Please also note on the plans that the new alarm must be interconnected with the smoke alarm in the home (per the alarm’s installation instructions).
- In addition, please provide the model number and information sheet about such detector/alarm
- Electrical Diagram
Energy storage: Can have one large AC disconnect (external, manually operated) for whole system or can have AC disconnect for battery and PV separate
- Label Page
For ESS:
- Include a sign with the exact wording. “ENERGY STORAGE SYSTEM DISCONNECT.” The sign must include the Nominal AC Voltage and Maximum DC voltage of the ESS system. CEC 706.15(C)
- Include a label containing the contact information for the qualified maintenance and service providers. CRC R328.11
- Custom Placards Required
- 1
Ground mount
- Ground Mount Fencing Required
- No
- Setback Front Yard
- 5
- Setback Back Yard
- 5
- Setback Side Yard
- 5