City of Monterey (CA)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2025 CALIFORNIA BUILDING CODE
2025 CALIFORNIA ELECTRICAL CODE
2025 CALIFORNIA FIRE CODE
2025 CALIFORNIA PLUMBING CODE
2025 CALIFORNIA MECHANICAL CODE
2025 CALIFORNIA ENERGY CODE
2025 CALIFORNIA RESIDENTIAL CODE
2025 CALIFORNIA ADMINISTRATIVE CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Adopted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- Existing Systems,Trenching
- How Many Plansets Required
- 3
- Revision Required
- 1
- New Planset Required For Module Swap
- 0
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 110
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,PV Breaker,Load Side Taps,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 1
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Provide following notes for photovoltaic panels.
- Photovoltaic circuits shall not be located in the same raceway, junction box, outlet box, etc. as non-photovoltaic circuits. CEC 690.4B
- Photovoltaic systems with DC circuits shall have arc-fault protection (when greater than 80 volts) and GFCI protection. CEC 690.11
- The photovoltaic main disconnecting breaker shall be located at the opposite end of the bus bar from the main disconnecting circuit breaker. CEC 705.12D
- A disconnecting means shall be provided for all photovoltaic equipment. If the equipment is energized from more than one source, the disconnecting means shall be grouped and identified. CEC 690.15
- When the photovoltaic inverters are connected on the load side of the main disconnect (after the main breaker), the sum of the photovoltaic disconnects shall not exceed 20% of the main electrical panel rating. CEC 690.64
- Provided a 3"x3" blank space above or near the sheet number for the city approval stamp at same location of each page
- Amend title sheet to include the following information:
Occupancy Classification
Specify Construction Type
Existing Building SQFT:
Solar Panels Installation SQFT:
Fire Sprinklers Within Residence?: (YES or NO)
Number of stories:(1, 2 or 3)
- Attachment Detail
Please provide a cross-section of the new roof structure. Please clarify if the existing roofing material will be removed and new roof insulation installed Identify weight of existing roofing and weight of new roof assembly, anchorage and roof penetrations.
- Electrical Diagram
Existing shall be interpreted as not being affected by the work within the scope of this permit
- Electrical Diagram Notes
Contractor is responsible to arrange for inspection of electrical equipment, including conductor terminations in panels, in a de-energized condition.
- Custom Placards Required
- 1
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim