City of Pleasanton (CA)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2025 CALIFORNIA BUILDING CODE
2025 CALIFORNIA ELECTRICAL CODE
2025 CALIFORNIA FIRE CODE
2025 CALIFORNIA PLUMBING CODE
2025 CALIFORNIA MECHANICAL CODE
2025 CALIFORNIA ENERGY CODE
2025 CALIFORNIA RESIDENTIAL CODE
2025 CALIFORNIA ADMINISTRATIVE CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Adopted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- Existing Systems,Trenching
- How Many Plansets Required
- 3
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- None
- Structural Calculations Required
- Yes - Battery
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 110
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
- **Structural Calcs:** According to PV Submittal requirements below, as long as we do not exceed 5lbs/sf we do not have to provide calcs. Run an IronRidge report (testing with Chen, Zigang) and attach with plans to prove that we are under. **Battery projects:** PE signature/seal required on PE calcs and mounting details
- Minimum Ground On Roof
- #10
Electrical
- AC Disconnect Required
- Yes
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,PV Breaker,Meter Adapter,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Currently the UL9540A for reduced spacing is not accepted. Must provide 3 feet separation between ESS units.
Provide ESS mounting hardware sheets. Details shall illustrate the minimum embedment into framing members, and the number of fasteners to be used.
For ESS inside of garage:
- Draw heat detector above ESS and include note: HEAT DETECTOR WILL BE HARD WIRED AND INTERCONNECTED WITH SMOKE DETECTORS INSIDE THE HOUSE.
- Provide Heat Detector specification sheet.
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- Yes
Plan set
- Plan Set Requirements
The PV plan pages must contain Greg's signature or be signed by the designer.
For ESS projects a note must be added to elevation diagram stating that ESS will be installed 3ft or more from any window or door leading into the dwelling.
Placard to state MULTIPLE SOURCES OF POWER
- Cover Page
* Indicate scope of work on the cover sheet specifying the PV system size, number of modules and panel upgrade/sub panel addition as applicable.
- Site Notes
For ESS projects a note must be added stating that ESS will be installed 3ft or more from any window or door leading into the dwelling.
- Electrical Diagram
Standard
- Label Page
- Custom Placards Required
- 1
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim