Town of Truckee (CA)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2025 CALIFORNIA BUILDING CODE
2025 CALIFORNIA ELECTRICAL CODE
2025 CALIFORNIA FIRE CODE
2025 CALIFORNIA PLUMBING CODE
2025 CALIFORNIA MECHANICAL CODE
2025 CALIFORNIA ENERGY CODE
2025 CALIFORNIA RESIDENTIAL CODE
2025 CALIFORNIA ADMINISTRATIVE CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 85
- Wind Notes
Risk Category I =110 mph Risk Category II = 120 mph Risk Category III & IV=130 mph
- Snow Load
- 999
- Snow Load Notes
Use link below to determine snow load:
https://townoftruckee.maps.arcgis.com/apps/webappviewer/index.html?id=964e3c9b34f0412a9aa27477c5d79fb0
https://www.townoftruckee.gov/200/Snow-Load-Design
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 48
- Structural Notes
**Seismic ** See CBC Section 1613 and ASCE 7-16, Chapter 11. Use Google map (http://maps.google.com/)or another source to determine site specific longitude and latitude. Use the USGS (http://www.usgs.gov/) website or NEHRP disk to determine S1 and Ss. Buildings are normally designed to seismic design category D. **Climate Criteria** The annual mean temperature from the National Climatic Data Center is 42.5º F. The 100 year return period air freezing index (99%) from the National Climatic Data Center is 1187. The lowest recorded temperature was -31º F in 1965. There are an average of six days annually with a low temperature of 0º F or lower. Depending upon the specific design application, the recommended winter design temperature should be taken somewhere within this range. The Town of Truckee is located in Climate Zone 16. ** **
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Meter Adapter,Line Side Taps,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Town of Truckee fire code requires a MCI switch located on the exterior of the home with-in 5 feet of the Main service panel. Please update line diagrams and Data Sheets with Shut down switch.
- Cover Page
On cover sheet please change wording under codes to state "Conforms to the Town of Truckee Municipal Code" instead of " As Adopted by Town of Truckee"
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim