Town of Firestone (CO)
NEC Code Version2023
Fire Code Version2018 Building Code
SolarAPP+ StatusTargeted
Wet Stamps RequiredDigital Structural
Fire Setback Enforced1
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2018 International Building Code
2018 International Residential Code
2018 International Plumbing Code
2018 International Mechanical Code
2018 International Existing Building Code
2018 International Fuel Gas Code
2018 International Property Maintenance Code
2018 International Swimming Pool and Spa Code
2018 International Energy Conservation Code
2023 National Electrical Code
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 1
- Revision Required
- 1
- New Planset Required For Module Swap
- 1
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category C
- Snow Load
- 35
- Snow Load Notes
30 lbs
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
- Provide stamped engineer structural analysis with letter from professional engineer addressing attachments and structural integrity for mounting to the existing structure will be adequate, and that the roof will support new addition. SE digital stamps on corresponding PV pages & PE Letter / Calcs. Exposure Category C 115 MPH wind speed roof snow load 30 PSF ground snow load 35 PSF
- All instances of the site address in the plans and engineering docs must call out the city as "Firestone" regardless of what the city is listed as in our system or on maps
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Meter Adapter,Load Side Taps,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
AHJ requires Critter Guard on every PV installation
They outsource their plan check through a company called them. Their phone number is .
- Cover Page
All instances of the site address in the plans and engineering docs must call out the city as "Firestone" regardless of what the city is listed as in our system or on maps
- Electrical Diagram
Standard
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim