City of Danbury (CT)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2021 INTERNATIONAL BUILDING CODE 2017 INTERNATIONAL CODE COUNCIL ANSI A 117.1. ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 2021 INTERNATIONAL EXISTING BUILDING CODE 2021 INTERNATIONAL PLUMBING CODE 2021 INTERNATIONAL MECHANICAL CODE 2021 INTERNATIONAL ENERGY CONSERVATION CODE 2020 NATIONAL ELECTRICAL CODE 2021 INTERNATIONAL RESIDENTIAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- Other (See Submission Notes)
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
* Size of each array shall not exceed 150' x 150'. Multiple arrays must 3' min from each other. * Hip Roofs: 3' access pathway required on any roof w/ modules on it * EXCEPTION: Roof Pitch < 9 degrees * EXCEPTION: single array system on one roof only and there is clear access on opposing slope * Single Ridge Roofs: 2015 Code * EXCEPTION: Roof Pitch < 9 degrees * EXCEPTION: single array system on one roof only and there is clear access on opposing slope * Roofs with Hips + Valleys: 2015 Code * EXCEPTION: Roof Pitch < 9 degrees
Structural & loads
- Wind Speed
- 119
- Wind Notes
Exposure Category B
- Snow Load
- 30
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,PV Breaker,Meter Adapter,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Custom Placards Required
- 1
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes
Max height: 15' Ground Screws allowed Minimum Freeze/Thaw Depth: 42" No gravel base required. Wiring and Conduit must be underground. Frost Protection needed. Septic documentation can be gathered from the Health Dept. 203. 797. 4500 -
- Setback Back Yard
- 15
- Setback Side Yard
- 15