District of Columbia (DOB) (DC)
Codes
- NEC Code Version
- 2014
- Fire Code Version
- 2015 Building Code
- Code List
2017 DISTRICT OF COLUMBIA BUILDING CODE
2015 INTERNATIONAL BUILDING CODE
2017 DISTRICT OF COLUMBIA RESIDENTIAL CODE
2015 INTERNATIONAL RESIDENTIAL CODE
2017 DISTRICT OF COLUMBIA ELECTRICAL
2014 NATIONAL ELECTRICAL CODE
2017 DISTRICT OF COLUMBIA FUEL GAS CODE
2015 INTERNATIONAL FUEL GAS CODE
2017 DISTRICT OF COLUMBIA MECHANICAL CODE
2015 INTERNATIONAL MECHANICAL CODE
2017 DISTRICT OF COLUMBIA PLUMBING CODE
2015 INTERNATIONAL PLUMBING CODE
2017 DISTRICT OF COLUMBIA PROPERTY MAINTENANCE CODE
2015 INTERNATIONAL PROPERTY MAINTENANCE CODE
2017 DISTRICT OF COLUMBIA FIRE CODE
2015 INTERNATIONAL FIRE CODE
2017 DISTRICT OF COLUMBIA ENERGY CONSERVATION CODE
2015 INTERNATIONAL ENERGY CONSERVATION CODE
2017 DISTRICT OF COLUMBIA EXISTING BUILDING CODE
2015 INTERNATIONAL EXISTING BUILDING CODE
2017 DISTRICT OF COLUMBIA GREEN CONSTRUCTION CODE
2012 INTERNATIONAL GREEN CONSTRUCTION CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- Other (See Submission Notes)
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Top Right
- Date On Stamps
- Date Plans are Stamped
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
- Flat roofs: Setbacks on roof required to be at least the same as the max system height above the roof deck
Structural & loads
- Wind Speed
- 115
- Snow Load
- 30
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #8
Electrical
- AC Disconnect Required
- Yes
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,Meter Adapter,Line Side Taps,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
For single and two family dwellings:
- Each array shall be no greater than 150 ft. in either axis.
- Locate roof access points, so that access ladders would not be placed in the plane of wall openings like doors or windows, or conflict with overhead obstruction.
- Layouts on hip roofs shall provide a 3 ft. wide, clear access pathway, capable of supporting the live load of firefighters, from the eave to the ridge on each roof slope where modules are located.
- Provide 2 such 3 ft. wide access pathways on each slope where modules are located on buildings with a single ridge.
- These requirements shall not apply to roofs with slopes of 2:12 or less.
- Verify compliance with IFC for facilitating smoke ventilation between arrays.
For other than single- and two-family dwellings:
- Each array shall be no greater than 150 ft. in either axis (systems are not limited to one array).
- Locate roof access points, so that access ladders would not be placed in the plane of wall openings like doors or windows, or conflict with overhead obstruction.
- Provide 6 ft. min. clear perimeter around the edge of roof, or 4 ft. where either axis of building is not greater than 250 ft.
- Access pathways should be capable of supporting the live load of firefighters.
- Verify compliance with IFC for facilitating smoke ventilation between arrays.
- Cover Page
Include the fire-rating of the roof and roof assembly as well as fire resistance rating of all roof penetrations sealing material.
- Site
All solar submissions now require a plat from the Office of the Surveyors office into the supporting documents folder. Please make sure the plat is filled out signed and shows proposed exterior work
- Please create ticket to Branch to have Plot ordered
- Electrical Diagram
TAPS: Identify the length of tap wire, not to exceed 10 feet on 3 line diagram
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim