City of Coconut Creek (FL)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2023 8TH EDITION FLORIDA BUILDING CODE: BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL
2023 8TH EDITION FLORIDA BUILDING CODE: MECHANICAL
2023 8TH EDITION FLORIDA BUILDING CODE: PLUMBING
2023 8TH EDITION FLORIDA BUILDING CODE: FUEL GAS
2023 8TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION
2023 8TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY
2021 8TH EDITION FLORIDA FIRE PREVENTION CODE, NFPA 1
2020 NATIONAL ELECTRIC CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 1
- Revision Required
- 1
- Rough Inspection
- Rough Electrical
- New Planset Required For Module Swap
- 1
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Ee Stamp Notes
Digitally Verified Signature
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Structural & loads
- Wind Speed
- 170
- Wind Notes
Exposure Category C ; HVHZ
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 48
- Structural Notes
SE & EE digital stamps on all PV pages, FL Statute, PE Letter & Calcs. WS 170 MPH
STAMPED FILES MAY NOT EXCEED 15MB
Digitally Verified Signature
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,PV Breaker,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
APPROVED PLANSET UPLOADED FOR CORRECT REFERENCE
Planset PDF file must be in the smallest file size without layers.
- Site Notes
All Jobs [Wind Speed: 170mph]
- Roof Plan
SHOW ATTACHMENTS AND RAIL ON ROOF PLAN
- Roof Plan Notes
All Jobs [ACCESS PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS, SUCH AS VENT PIPES, CONDUIT, OR MECHANICAL EQUIPMENT. NFPA 1-11.12.3.2.3.4.]
- Attachment Detail
PROVIDE ATTACHMENT NOA
CANNOT USE RAILESS
FLASHKIT PRO ONLY
- Electrical Diagram
Second disconnect required if system is separated by gate. Disconnect to be called them
Taps
- Piercing taps NOT ALLOWED
- Utilize Polaris Taps
- Electrical Diagram Notes
All Jobs [Rapid shutdown to initiate within 30 seconds]
- Label Page
FLORIDA - 2020 NFPA 1:11 CAD BLOCK
- Label Page Notes
All Jobs [THE LABEL SHALL BE REFLECTIVE, WITH ALL LETTERS CAPITALIZED AND HAVING A MINIMUM HEIGHT OF 3/8 IN. (9.5 MM), IN WHITE ON A RED BACKGROUND. (NFPA 1-11.12.2.1.1.2)]
- Custom Placards Required
- 1
- Placards Notes
AC disconnect must have reflective, water resistant sticker/placard
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim