City of Lakeland (FL)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2023 FLORIDA BUILDING CODE 8TH EDITION: BUILDING
2023 FLORIDA BUILDING CODE 8TH EDITION: RESIDENTIAL
2023 FLORIDA BUILDING CODE 8TH EDITION: MECHANICAL
2023 FLORIDA BUILDING CODE 8TH EDITION: PLUMBING
2023 FLORIDA BUILDING CODE 8TH EDITION: FUEL GAS
2023 FLORIDA BUILDING CODE 8TH EDITION: ENERGY CONSERVATION
2023 FLORIDA BUILDING CODE 8TH EDITION: EXISTING BUILDING
2023 FLORIDA BUILDING CODE 8TH EDITION: ACCESSIBILITY
2023 FLORIDA FIRE PREVENTION CODE 8TH EDITION
2020 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Testing
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Ee Stamp Notes
Digital stamps, stamped pages need to be separated.
Digitally Verified Signature
- Stamp Location On Plans
- Top Right
- Date On Stamps
- Date Plans are Stamped
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Setback must start at load bearing wall.
EX: 1ft eave, setback must be 4ft
Structural & loads
- Wind Speed
- 145
- Wind Notes
Exposure Category C ; HVHZ
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 48
- Structural Notes
Entire planset including specs need to be separated in a zip file
Digitally Verified Signature
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,Line Side Taps,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
FOR SEEB: ALWAYS ADD THE BACKUP INTERFACE MANUFACTURER SPEC SHEETS
- Separate ESS Disconnect Required
- No
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Plans to be separated
- Roof Plan
- Roof Plan Notes
All Jobs [Layout subject to change. // Conduit will be higher than 7/8 inches above the roof.]
- Electrical Diagram
- Electrical Diagram Notes
LST [Existing service complies with NEC 312.8. Disconnects will be grouped per NEC 230.72]
All Jobs [Interconnection Method subject to change // Solar Modules are Nationally Recognized Test Lab (NRTL), see spec sheet for details]
- Label Page
FLORDIA - 2020
- Custom Placards Required
- 1
- Placards Notes
Site Placard is Required of layout.
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim