City of Melbourne (FL)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2023 8TH EDITION FLORIDA BUILDING CODE: BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL
2023 8TH EDITION FLORIDA BUILDING CODE: MECHANICAL
2023 8TH EDITION FLORIDA BUILDING CODE: PLUMBING
2023 8TH EDITION FLORIDA BUILDING CODE: FUEL GAS
2023 8TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION
2023 8TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY
2023 8TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA)
2020 NATIONAL ELECTRIC CODE (NEC)
- ASCE Code Specification
- ASCE 7-22
SolarAPP+ & submittal
- SolarAPP+ Status
- Not accepted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- Other (See Submission Notes)
- Revision Required
- 0
- Rough Inspection
- Rough Electrical
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Ee Stamp Notes
Digitally Verified Signature
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard modified setbacks are ok. Portrait orientation only (Landscape is not allowed)
Structural & loads
- Wind Speed
- 151
- Wind Notes
Exposure Category C ; HVHZ
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 48
- Structural Notes
SE / EE digital stamps on all PV pages, FL Statute & PE Letter / Calcs. WS 150 MPH Show compliance with FBC R905.17.1. Design uplift pressures in component and cladding pressure zones 1 and 2 exceed module design uplift pressure rating.
Digitally Verified Signature
- Minimum Ground On Roof
- #10
Electrical
- AC Disconnect Required
- Yes
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,Load Side Taps,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
- BOS Restrictions
Line Side Taps
Show compliance with NEC 230.46. Pressure connectors and devices for splices and taps installed on service conductors shall be marked “Suitable for use on the line side of the service equipment” or equivalent. The only insulation piercing connector that is certified for use on the line side of the service equipment is the ILSCO IPC-250-4/0. Submit manufacturer specification sheet for line-side connector which is listed suitable for the use.
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Modules cannot be installed over vents
All projects must provide wind zones per ASCE 7-22
See WindZone clarification ---> ARTICLE
- Cover Page
- Site Notes
EXAMPLE PROJECT ----> EXAMPLE
- Roof Plan Notes
All Jobs [Modules shall not be installed over plumbing vent terminals. Plumbing vent terminals shall project a minimum of 6" above the roof surface. FBC Residential R301.1 Compliant]
- Attachment Detail
Comp Shingle ----> add note "Bostik NOA" and NOA found in files
Tile Roof ----> add note "GAF NOA" and NOA found in files
- Attachment Detail Notes
Max rail overhang 33% of attachment spacing
- Electrical Diagram
LST, EGC must be separate from other conductors (use FL LST blocks)
All sub panels require main breaker
POLARIS PLUGS ONLY!
- Electrical Diagram Notes
All Jobs [THE POWER SOURCE OUTPUT BREAKER MUST BE PLACED AT THE “OPPOSITE END” OF THE INTERIOR LOAD CENTER BUSBAR WHERE THE SERVICE DISCONNECTING MEANS IS EQUIPPED WITH FEED-THROUGH CONDUCTORS IN ORDER TO COMPLY WITH NEC 705.12(B)(2)(3)(B). IF THE CONNECTION IS MADE TO THE BUSBAR OF A PANELBOARD THAT SUPPLIES LUGS CONNECTED TO FEED-THROUGH CONDUCTORS AN ADDITIONAL OCPD SHALL BE INSTALLED ON THE LOAD-SIDE OF THE POWER SOURCE OUTPUT CONNECTION TO LIMIT THE CURRENT ON THE FEEDER CONDUCTORS AND INTERIOR PANEL SUPPLIED BY FEED-THROUGH CONDUCTORS]
- Label Page
FLORIDA - 2020 EMERGENCY
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim