City of West Park (FL)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2023 8TH EDITION FLORIDA BUILDING CODE: BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL
2023 8TH EDITION FLORIDA BUILDING CODE: MECHANICAL
2023 8TH EDITION FLORIDA BUILDING CODE: PLUMBING
2023 8TH EDITION FLORIDA BUILDING CODE: FUEL GAS
2023 8TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION
2023 8TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY
2023 8TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA)
2020 NATIONAL ELECTRIC CODE (NEC)
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 2
- Revision Required
- 1
- Rough Inspection
- Racking Inspection
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Wet Structural,Wet Electrical
- Structural Calculations Required
- Yes
- Ee Stamp Notes
This AHJ does not accept stamped signature. Wet signature required
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 165
- Wind Notes
Exposure Category C ; HVHZ
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
The AHJ requires wet plans. Digital signed and sealed plans are not an option for the AHJ.
Signed and sealed plans to the branch, along with the SIF, Structural Calculations, and PE letter.
This AHJ does not accept stamped signature. Wet signature required
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,Line Side Taps,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Electrical Diagram
Taps
- Do not list piercing taps for line side tap connections. The only fitting we can use for line side taps in these AHJs are insulated Polaris taps.
- Label Page Notes
2/19/25:
- Provide a permanent plaque or directory, denoting the location of each power source disconnecting means for the building, per 11.12.2.1.4.4. 2. On the plaque or directory, provide the wording CAUTION: MULTIPLE SOURCES OF POWER; per 11.12.2.1.4.5 and NFPA 70 �?? Article 705.10. 3. [Remove the existing CAD template text and replace with the AHJ required text.]
- For the plaque or directory, posted diagrams shall be correctly oriented with respect to the diagram's location; if posted on the West side of the building, north should be oriented to the Left, (Panels should be located at the bottom of the diagram per 11.12.2.1.4.6 and NFPA 70 [Placard will be posted on equipment, use Aurora to help determine new north direction when the building is rotated for the equipment to face the bottom of the placard]
- Custom Placards Required
- 1
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim