County of Marion (FL)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2023 8TH EDITION FLORIDA BUILDING CODE: BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL
2023 8TH EDITION FLORIDA BUILDING CODE: MECHANICAL
2023 8TH EDITION FLORIDA BUILDING CODE: PLUMBING
2023 8TH EDITION FLORIDA BUILDING CODE: FUEL GAS
2023 8TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION
2023 8TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY
2023 8TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA)
2020 NATIONAL ELECTRIC CODE (NEC)
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Not accepted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- Other (See Submission Notes)
- Revision Required
- 1
- Rough Inspection
- Rough Electrical
- New Planset Required For Module Swap
- 1
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Ee Stamp Notes
- Both SE and EE engineers to sign and seal the plans.
- A letter is required outlining which engineer is the SE and which is the EE
- Digitally Verified Signature
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
- FBCR 324.6, FBC 3111.3.4, Florida Fire Prevention code 11.12.2.2
- MINIMUM OF 36" PATHWAY REQUIRED WHERE THE TWO PANELED PLANES MEET
Structural & loads
- Wind Speed
- 145
- Wind Notes
Exposure Category C
- Snow Load
- 0
- Reducible Snow Load Allowed
- 0
- Max Attachment Spacing
- 48
- Structural Notes
- SE / EE digital stamps on all PV pages, FL Statute & PE Letter / Calcs.
- AHJ will not accept restamped structural calcs from a previous version of plans.
- All stamped plans and letters need to be stamped with same date.
- Provide signed/sealed documentation stating specifically that "the structural capacity of the existing roof system is adequate to carry the loads imposed by the panels and the mounting system being used."
- 18 mb max file size for submissions, This includes the stamped set of plans.
- Both SE and EE engineers to sign and seal the plans.
- A letter is required outlining which engineer is the SE and which is the EE
- Digitally Verified Signature
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,PV Breaker,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- No
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
- PV panels CAN NOT be installed on manufactured mobile homes
- Plan PDF needs to be flattened and reduced to the smallest file size before sending to the PE for stamps.
- Attachment Detail
- Attachment Detail Notes
All Jobs [existing roof can withstand the additional weight]
- Electrical Diagram
Include Riser Diagram in files (fill out diagram)
Centerfed 120% allowed
Taps:
- Provide manufacturers listing and approval specifications for Tap connection hardware
- Electrical Diagram Notes
LST [TAPs are suitable for use on the line side of the service equipment]
- Label Page
FLORIDA 2020 CAD BLOCK
- Custom Placards Required
- 1
- Placards Notes
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes
- Do you require ground mounts to have additional fencing or meshing protecting the array? As per NEC Article 690.
- GIS map to get property Subdivision type Interactive Map
- Zoning Code Ordinance to get Property Setbacks DIVISION 2. - ZONING CLASSIFICATION | Land Development Code | Marion County, FL | Municode Library
- Setback Front Yard
- 10
- Setback Back Yard
- 8
- Setback Side Yard
- 8