Town of Davie (FL)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2023 8TH EDITION FLORIDA BUILDING CODE
2023 8TH EDITION FLORIDA RESIDENTIAL CODE
2023 8TH EDITION FLORIDA MECHANICAL CODE
2023 8TH EDITION FLORIDA PLUMBING CODE
2023 8TH EDITION FLORIDA FUEL GAS CODE
2023 8TH EDITION FLORIDA ENERGY CONSERVATION CODE
2023 8TH EDITION FLORIDA EXISTING BUILDING CODE
2023 8TH EDITION FLORIDA ACCESSIBILITY CODE
2023 8TH EDITION FLORIDA FIRE PREVENTION CODE
2020 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 2
- Revision Required
- 1
- Rough Inspection
- Footing inspection
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Ee Stamp Notes
Digitally Verified Signature
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 170
- Wind Notes
Exposure Category C ; HVHZ
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 48
- Structural Notes
PE Stamps ; SE / EE digital stamps on all PV Pages & PE Letter / Calcs. WS 170 MPH SEPARATE stamped PV pages. AHJ requires special building inspector form (SIF - attached below)
Digitally Verified Signature
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,PV Breaker,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
ATTACH SIF (SEE FILES)
- Roof Plan Notes
All Jobs [ULTIMATE WIND SPEED 170 MPH // EXPOSURE C PER FBC 1620.2.2]
- Electrical Diagram
ADD DC CALCS TO THE PLANS
- Label Page
FLORIDA 2020 CAD BLOCK
- Custom Placards Required
- 1
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim