County of Blaine (ID)
Codes
- NEC Code Version
- 2017
- Fire Code Version
- 2018 Building Code
- Code List
2018 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL RESIDENTIAL CODE
2012 INTERNATIONAL ENERGY CONSERVATION CODE
2018 INTERNATIONAL EXISTING BUILDING CODE
2018 INTERNATIONAL SWIMMING POOL AND SPA CODE
2018 INTERNATIONAL FIRE CODE
- IEBC Accepted
- 1
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Date Plans are Stamped
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
- Snow Load
- 999
- Snow Load Notes
See attached file "Snow Load Requirements"
115mph is Basic Wind Speed North Fork to Smiley Creek: 150 PSF North of Ketchum to North Fork: 125 PSF West of Ketchum to western end of platted Board's Lower Ranch: 110 PSF West of western end of platted Lower Board Ranch: 125 PSF East of Triumph: 125 PSF North of Bellevue to south of Ketchum: 100 PSF Picabo to south of Bellevue: 65 PSF Carey including south and east of Carey: 50 PSF
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,PV Breaker,Meter Adapter,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Roof Plan
Show roof access points
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes
Ground mounted systems shall be located at minimum 1.1 times the distance of vertical height of the solar collector system from property lines, residential structures and roads on subject property. Ground screws allowed. Min Freeze/Thaw Depth: 32" 15' max height Collector systems panels located in the designated floodplain are two feet (2') above base flood elevation. Septic documentation can be gathered from South Central Health District Floodplain and Wetland requirements are outlined in "Solar Zoning Regulations" (attached File)