City of East Peoria (IL)

Illinois Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2020
Fire Code Version2015 Building Code
Wet Stamps RequiredDigital Structural
Fire Setback Enforced1

Codes

NEC Code Version
2020
Fire Code Version
2015 Building Code
Code List

2018 INTERNATIONAL BUILDING CODE

2018 INTERNATIONAL ENERGY CONSERVATION CODE

2018 INTERNATIONAL FIRE CODE

2018 INTERNATIONAL MECHANICAL CODE

2018 INTERNATIONAL PROPERTY MAINTENANCE CODE

2018 INTERNATIONAL RESIDENTIAL CODE

2018 NFPA 101 LIFE SAFETY CODE

2020 NATIONAL ELECTRICAL CODE

ILLINOIS STATE PLUMBING CODE LATEST EDITION

ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

Revision Required
1
Rough Inspection
None
New Planset Required For Module Swap
0

Stamps

Ee Stamp Required On SLD
No
Wet Stamps Required
Digital Structural
Structural Calculations Required
Yes
Stamp Location On Plans
Unspecified

Fire setbacks

Fire Setback Enforced
1
Setback Notes

Standard

Structural & loads

Wind Speed
90
Snow Load
20
Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Minimum Ground On Roof
#10

Electrical

Electrical Load Calcs Required
Derates
Allowed POI
Load Side Taps,Line Side Taps,PV Breaker,Meter Adapter
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
0.91

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes

Standard

Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Plan set

Plan Set Requirements

SLD needs to show Lever bypass socket

Custom Placards Required
0

Ground mount

Ground Mount Fencing Required
Mesh/Scrim
Ground Mount Notes

GMs not allowed in Front Yard

Height

  • a. Ground-mount solar energy systems shall not exceed 20 feet in height when oriented at maximum tilt.
  • b. Ground-mount solar energy systems placed in the front yard through a special use shall not exceed 30 inches above grade.

Setbacks

  • a. Ground-mount solar energy systems shall meet the accessory structure setbacks for the zoning district in which the system is located.
  • b. Ground-mount solar energy systems shall not extend into the side yard or rear yard setback at any design tilt.
Setback Back Yard
5
Setback Side Yard
5