City of East Peoria (IL)
NEC Code Version2020
Fire Code Version2015 Building Code
Wet Stamps RequiredDigital Structural
Fire Setback Enforced1
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2015 Building Code
- Code List
2018 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL ENERGY CONSERVATION CODE
2018 INTERNATIONAL FIRE CODE
2018 INTERNATIONAL MECHANICAL CODE
2018 INTERNATIONAL PROPERTY MAINTENANCE CODE
2018 INTERNATIONAL RESIDENTIAL CODE
2018 NFPA 101 LIFE SAFETY CODE
2020 NATIONAL ELECTRICAL CODE
ILLINOIS STATE PLUMBING CODE LATEST EDITION
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 90
- Snow Load
- 20
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,Line Side Taps,PV Breaker,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
SLD needs to show Lever bypass socket
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Ground Mount Notes
GMs not allowed in Front Yard
Height
- a. Ground-mount solar energy systems shall not exceed 20 feet in height when oriented at maximum tilt.
- b. Ground-mount solar energy systems placed in the front yard through a special use shall not exceed 30 inches above grade.
Setbacks
- a. Ground-mount solar energy systems shall meet the accessory structure setbacks for the zoning district in which the system is located.
- b. Ground-mount solar energy systems shall not extend into the side yard or rear yard setback at any design tilt.
- Setback Back Yard
- 5
- Setback Side Yard
- 5