City of Harvard (IL)
Codes
- NEC Code Version
- 2011
- Fire Code Version
- 2015 Building Code
- Code List
2012 International Building Code 2012 International Residential Code 2012 International Fire Code 2011 National Electrical Code
- IEBC Accepted
- 1
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 1
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 30
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Load Side Taps,Line Side Taps,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Attachment Detail
For manufactured mounting systems, fill information on the mounting system below: a. Mounting System Manufacturer ________________ b. Product Name and Model # ______________ c. Total Weight of PV Modules and Rails ___________ lbs d. Total Number of Attachment Points ______ (attachment points must be equally distributed across the array. e. Weight per attachment ___________ lbs f. Maximum Spacing between Attachment Points on a Rail ______ in (see product manual for maximum spacing allowed based on maximum design wind speed). g. Total Surface Area of PV Modules (square feet) _________ ft2 h. Distributed Weight of PV Module on Roof (c%f) _____ lbs/ft2
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim