County of St. Clair (IL)
NEC Code Version2011
Fire Code Version2018 Building Code
SolarAPP+ StatusNot accepted
Wet Stamps RequiredDigital Structural,Digital Electrical
Fire Setback Enforced1
Codes
- NEC Code Version
- 2011
- Fire Code Version
- 2018 Building Code
- Code List
2012 INTERNATIONAL BUILDING CODE
2012 INTERNATIONAL RESIDENTIAL CODE
2018 ILLINOIS ENERGY CONSERVATION CODE
2011 NATIONAL ELECTRICAL CODE
- IEBC Accepted
- 1
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Not accepted
- Any SolarAPP+ Restrictions
- 1
- How Many Plansets Required
- 1
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Snow Load
- 25
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- AC Disconnect Required
- Yes
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Meter Adapter,Load Side Taps,PV Breaker,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
- BOS Restrictions
- AHJ Requirement: Only breaker, Polaris taps, or Milbank dual lugs are allowed.
- BATTERIES MUST BE INSTALLED INSIDE, PLEASE CONFIRM WITH LOCAL BRANCH FOR DETAILS.
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
- BATTERIES MUST BE INSTALLED INSIDE, PLEASE CONFIRM WITH LOCAL BRANCH FOR DETAILS.
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Standard
- Cover Page
Standard
- Site
Site plan must show barriers or screening from neighbors
- Roof Plan
Standard
- Attachment Detail
Standard
- Electrical Diagram
Standard
- Electrical Diagram Notes
All Jobs [AHJ REQUIREMENT: BREAKER OR POLARIS TAPS/MILBANK DUAL LUGS ONLY]
- Label Page
Standard
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim