Solar Sanity Checksolar, decoded Independent. Nothing you type leaves your browser.

Village of Homewood (IL)

Illinois Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2017
Fire Code Version2015 Building Code
SolarAPP+ StatusTargeted
Wet Stamps RequiredDigital Structural
Fire Setback Enforced1

Codes

NEC Code Version
2017
Fire Code Version
2015 Building Code
Code List

2018 International Building Code

2018 International Residential Code

2003 Electrical Code Administrative Provisions

2017 National Electrical Code

2018 International Mechanical Code

2018 International Energy Conservation Code

2018 International Existing Building Code

2018 International Property Maintenance Code

2018 International Fuel Gas Code

2018 NFPA 101 Life Safety Code

ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

SolarAPP+ Status
Targeted
Any SolarAPP+ Restrictions
1
SolarAPP+ Restrictions
MPU,Derate
How Many Plansets Required
1
Revision Required
1
Rough Inspection
None
New Planset Required For Module Swap
0

Stamps

Wet Stamps Required
Digital Structural
Structural Calculations Required
Yes
Stamp Location On Plans
Unspecified
Date On Stamps
Expiration Date

Fire setbacks

Fire Setback Enforced
1
Setback Notes

2012 IBC 3' Setback from Rake and 3' Setback along ridge

Structural & loads

Wind Speed
115
Wind Notes

Exposure Category B

Snow Load
30
Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Structural Notes

structural engineer should not sign or seal any electrical specifications

Minimum Ground On Roof
#10

Electrical

Electrical Load Calcs Required
Derates
Allowed POI
PV Breaker,Load Side Taps,Meter Adapter,Line Side Taps
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
1

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes

Standard

Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Plan set

Attachment Detail

All Jobs [LENGTH OF SCREW THROUGH ALL MEMBERS TO ACHIEVE MINIMUM EMBEDMENT]

Electrical Diagram


Electrical Diagram Notes

All Jobs [CLEAR WORKING SPACE AROUND THE PANEL IS REQUIRED (NEC110.26) // JUNCTION BOX AND CONNECTORS LOCATED ON ROOF ARE RATED FOR WET LOCATION]

Custom Placards Required
0

Ground mount

Ground Mount Fencing Required
Mesh/Scrim
Compiled from public records, 2026. Requirements change with code cycles and local amendments. Verify with the Village of Homewood (IL) building department before you rely on this, and treat it as a research head start, not a ruling. Getting quotes? Run them through the quote checker first.