Illinois Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2017
Fire Code Version2015 Building Code
SolarAPP+ StatusTargeted
Wet Stamps RequiredDigital Structural
Fire Setback Enforced1

Codes

NEC Code Version
2017
Fire Code Version
2015 Building Code
Code List

2018 INTERNATIONAL BUILDING CODE, WITH AMENDMENTS

2018 INTERNATIONAL RESIDENTIAL CODE, WITH AMENDMENTS

2017 NATIONAL ELECTRIC CODE, WITH AMENDMENTS

2014 ILLINOIS PLUMBING CODE, WITH AMENDMENTS

2018 INTERNATIONAL MECHANICAL CODE, WITH AMENDMENTS

2018 INTERNATIONAL FIRE PREVENTION CODE, WITH AMENDMENTS

2018 INTERNATIONAL FUEL GAS CODE, WITH AMENDMENTS

2018 INTERNATIONAL PROPERTY MAINTENANCE CODE, WITH AMENDMENTS

2015 STATE OF ILLINOIS ENERGY CONSERVATION CODE

ILLINOIS ACCESSIBILITY CODE - MOST RECENT EDITION

NFPA 101 LIFE SAFETY CODE

2012 VOH SUBDIVISION ORDINANCE

VOH ZONING CODE

IEBC Accepted
1
ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

SolarAPP+ Status
Targeted
Any SolarAPP+ Restrictions
1
SolarAPP+ Restrictions
MPU,Derate
How Many Plansets Required
3
Revision Required
1
Rough Inspection
None
New Planset Required For Module Swap
0

Stamps

Wet Stamps Required
Digital Structural
Structural Calculations Required
Yes
Stamp Location On Plans
Unspecified
Date On Stamps
Expiration Date

Fire setbacks

Fire Setback Enforced
1
Setback Notes

12 IBC/IRC 3' Fire Setback

Structural & loads

Wind Speed
115
Wind Notes

Exposure Category B

Snow Load
30
Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Structural Notes

Standard

Minimum Ground On Roof
#10

Electrical

Electrical Load Calcs Required
Derates
Allowed POI
PV Breaker,Meter Adapter,Line Side Taps,Load Side Taps
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
1

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes

Standard

Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Plan set

Electrical Diagram

Standard

Custom Placards Required
0

Ground mount

Ground Mount Fencing Required
Mesh/Scrim