Solar Sanity Checksolar, decoded Independent. Nothing you type leaves your browser.

Village of Oak Park (IL)

Illinois Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2017
Fire Code Version2018 Building Code
SolarAPP+ StatusTargeted
Wet Stamps RequiredDigital Structural
Fire Setback Enforced1

Codes

NEC Code Version
2017
Fire Code Version
2018 Building Code
Code List

2021 International Residential Code (IRC)

2021 State of Illinois Energy Conservation Code

2021 International Existing Building Code

2017 National Electrical Code (NEC)

IEBC Accepted
1
ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

SolarAPP+ Status
Targeted
Any SolarAPP+ Restrictions
1
SolarAPP+ Restrictions
MPU,Derate
How Many Plansets Required
1
Revision Required
1
Rough Inspection
Rough Electrical
New Planset Required For Module Swap
0

Stamps

Wet Stamps Required
Digital Structural
Structural Calculations Required
Yes
Stamp Location On Plans
Unspecified
Date On Stamps
Expiration Date

Fire setbacks

Fire Setback Enforced
1
Setback Notes

Standard

Structural & loads

Wind Speed
115
Wind Notes

Exposure Category B

Snow Load
30
Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Structural Notes

snow load to 30 as stated on the letter **(per Bukalski, Mark DCR 11/16/20)**

Minimum Ground On Roof
#10

Electrical

Electrical Load Calcs Required
Derates
Allowed POI
Load Side Taps,Line Side Taps,Meter Adapter,PV Breaker
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
1

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes

Standard

Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Plan set

Site

DIMENSION FROM NEW EQUIPMENT TO PROPERTY LINE (minimum 1ft setback required)

Electrical Diagram

Standard

Label Page

Show the roof plane placard on the labels page for the Engraved red sign to be affixed to structure in the area of emergency disconnection switches.

Custom Placards Required
1
Placards Notes
  • A site map placard is required to be on site to pass inspection

Ground mount

Ground Mount Fencing Required
Mesh/Scrim