Village of Skokie (IL)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2015 Building Code
- Code List
2021 INTERNATIONAL RESIDENTIAL CODE WITH AMENDMENTS
2021 INTERNATIONAL BUILDING CODE WITH AMENDMENTS PAGE
2021 STATE OF ILLINOIS PLUMBING CODE
2020 NATIONAL ELECTRICAL CODE WITH AMENDMENTS
2021 INTERNATIONAL MECHANICAL CODE WITH AMENDMENTS
2021 INTERNATIONAL FUEL GAS CODE WITH AMENDMENTS
2021 INTERNATIONAL ENERGY CONSERVATION CODE WITH ILLINOIS AMENDMENTS
2021 INTERNATIONAL FIRE CODE WITH AMENDMENTS
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 1
- Revision Required
- 1
- Rough Inspection
- Footing inspection
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
CUSTOM REQUIREMENTS:
- 48โ wide access path from the street facing side of the roof and to an adjacent or opposite roof
- 36" on both sides of the ridge
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 30
- Snow Load Notes
30 PSF
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
PE Stamps; SE digital stamps on corresponding PV pages & PE Letter / Calcs. WS 115 MPH GSL 30 PSF
- Minimum Ground On Roof
- #10
Electrical
- AC Disconnect Required
- Yes
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,Load Side Taps,PV Breaker,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Service Ground Requirements
AHJ requires Emergency disconnect installed outside next to meter
- Temperature Rating
- 90
- De Rating Ampacity
- 1
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Meter collar adapters not allowed
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- Yes - with dimensions
Plan set
- Electrical Diagram
Add note to SLD for all line side/supply side taps:
- Electrical Diagram Notes
LINE SIDE/SUPPLY SIDE TAP WILL NOT BE ALLOWED ON OUTDATED EQUIPMENT
Tesla Backup switch and meter collar adapters are not approved for use within the Village of Skokie.
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim