City of Haverhill (MA)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
10TH EDITION OF THE MA STATE BUILDING CODE 780
2021 INTERNATIONAL BUILDING CODE W/780 CMR
2021 INTERNATIONAL RESIDENTIAL CODE W/780 CMR
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 INTERNATIONAL MECHANICAL CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2021 INTERNATIONAL FIRE CODE
2023 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- Other (See Submission Notes)
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Ee Stamp Notes
- No EE required
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
The Haverhill Fire Department requests that roof mounted solar arrays are installed with the following setbacks:
Gable roof: not less than two 3 foot wide access pathways from the eave to the ridge on each roof slope where solar panels are located.
- One access pathway shall be provided on the street or driveway side of the roof
- No Overhead Electrical crossing access pathways
- NO conduit across access pathways.
- No overgrown trees or shrubs below access pathways.
Setbacks at ridge (Both Sides):
- 18โ if PV coverage < 33%
- (If sprinkled < 66%)
- 36โ if PV coverage >33%
- (If sprinkled > 66%)
Hip roof: one 3-foot-wide access pathway from the eave to the ridge on each roof slope where panels are located
Hip/valley: 18โ wide access pathway from the eave to the ridge
ESS to follow NFPA 855 2023 ed. If applicable
Fire set backs for flat roofs
Due to the fact that there is no current set back wording in NFPA 1 on residential flat roofs The Haverhill Fire Department requests that FLAT ROOF mounted solar arrays are installed with the following setbacks:
- Around the perimeter of the roof at least an 18โ set back.
- One 36โ access pathway shall be provided on the street or driveway side of the roof running across the roof from EAVE to EAVE.
- From EAVE to EAVE in the opposite direction a minimum 18โ escape pathway running at the center of the roof forming a + pattern. This allows firefighter escape points at all Eave lines
- No Overhead Electrical crossing access pathways
- NO conduit across access pathways.
- No overgrown trees or shrubs below access pathways.
- ESS to follow NFPA 855 2023 ed. If applicable
Structural & loads
- Wind Speed
- 120
- Wind Notes
Exposure Category B
- Snow Load
- 50
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Load Side Taps,Line Side Taps,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 1
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
No battery can be placed in the basement
If Basement is the only please please reach out to BM for review
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Roof Plan
-Conduit will need to be run internally or in ways that would avoid crossing the fire pathways.
- Attachment Detail
Gable Roof: Not less than two 3 foot wide access pathways from the eave to the ridge on each roof slope where panels are located One access pathway shall be on the street or driveway side of the roof If solar panels are to be installed on two sides of a roof, panels shall be location no higher than 3 feet below the ridge on one side to allow for the ventilation of smoke in the event of a fire. The other side of the roof the panels shall be located no higher than 18 inches below the ridge. Hip Roof: On 3 foot wide access pathway from the eave to the ridge on each roof slope where panels are located Hip/Valley: 18 inch wide access pathway from the eave to the ridge
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Ground Mount Notes
System > 10kW
- Front - 100'
- Side - 75" ( lot abuts a residential district - 100')
- Back - 75' ( lot abuts a residential district - 100')