County of Baltimore (MD)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL RESIDENTIAL CODE
2021 INTERNATIONAL MECHANICAL CODE
2021 NATIONAL STANDARD PLUMBING CODE
2021 INTERNATIONAL ENERGY CODE
2021 NFPA 101 LIFE SAFETY CODE
2021 INTERNATIONAL FIRE CODE
2023 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 1
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes - 10kW+
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
- MUST HAVE 36'' PATHWAY FOR SETBACKS. NOT 18''
- Roof Access Point - This is the point at which the firefighters first access the roof.
All Buildings:
- This point may not be above windows or doors and must be free of overhead obstructions such as tree limbs, wires, or signs above or below the access point.
- This point must be located at a strong point of building construction.
One and Two Family Buildings:
- The access point is located at the bottom of each access pathway.
- See description below.
Other than One and Two Family Buildings:
- There must be a minimum six feet clear perimeter along the edge of the roof.
- If either axis of the building is 250 feet or less in length, a reduction to a minimum four foot clear perimeter along the edge of the roof shall be permitted.
Structural & loads
- Wind Speed
- 90
- Wind Notes
Design wind speed (Risk Categories I & II) 90 MPH Nominal 3 second gust (minimum design)
- Snow Load
- 30
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
- ### IF KW IS LESS THAN 10 KW, STAMPS ARE NOT NEEDED **Note:** Design professional shall provide detail information as to compliance with the International Conservation Code 2015 Edition, Energy Efficiency for Zone 4A.
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Line Side Taps,Load Side Taps,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
- BOS Restrictions
If there is to be a fused disco inside, use a flush-mounted breaker housing instead of a surface-mounted knife-blade switch. Former is aesthetically pleasing. Latter is not.
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
If there is to be a fused disco inside, use a flush-mounted breaker housing instead of a surface-mounted knife-blade switch. Former is aesthetically pleasing. Latter is not.
Check service cable to see if frayed. If yes, the project will require replacement to pass inspection.
Signage Requirements:
- All signage must be weather resistant, and otherwise suitable for the environment.
Main Service Disconnect Requirements:
- Must be affixed to the panel.
- Must be red and white lettering.
- Must be in capital letters.
- Must be three-fourths inches in height.
- Must read: [Warning: Photovoltaic Power Source].
- Must be reflective
Circuit Disconnect Requirements:
- Must be adjacent to the breaker.
- Must be contrasting colors.
- Must be in capital letters.
- Must be three-eighths inches in height.
- Must read [Photovoltaic Disconnect].
DC Only Requirements: (This section specifies the DC system signage requirements for conduits, enclosures, cable assemblies, combiner boxes, and junction boxes.)
- Must be located every 10 feet, at turns, above and below penetrations, on every combiner box, and on every junction box.
- Must be red with white lettering.
- Must be in capital letters.
- Must be three-eighths inches in height.
- Must read: [Warning: Photovoltaic Power Source].
- Must be reflective.
What are the local building design requirements in Baltimore County? footing depth 30 inches
- pole buildings 48 inches minimum
- design wind pressure 14.4 psf
- flood protection elevation 10.4 feet (Back River and south)
- 11.2 feet (north of Back River)
- Cover Page
AHJ does not do plan review if the project is under 10 kW. All requirements in the DB should still apply to projects under 10kW
- Electrical Diagram
- If POI is a Line Side Tap, two disconnects are required. One fused, one non-fused.
- If there is to be a fused disco inside, use a flush-mounted breaker housing instead of a surface-mounted knife-blade switch. Former is aesthetically pleasing. Latter is not.
- Surge protector required to be within fused ac disconnect for lineside taps only. Please add surge protector to the BOM page for lineside taps, does not need to be shown on SLD.
- Custom Placards Required
- 0
- Non Standard Planset Requirements
- BOS Elevation
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Ground Mount Notes
Ground Mounted PV Arrays
- A clear 10 feet area around the installation shall be provided.
- A gravel or other non-combustible base shall be installed and maintained under and around the installation.
- Side and back yard is 2.5'
- Front setback has to be the start of the rear foundation wall of the house.
- Setback Back Yard
- 2
- Setback Side Yard
- 2