City of Woodbury (MN)
Codes
- NEC Code Version
- 2017
- Fire Code Version
- 2018 Building Code
- Code List
2020 MINNESOTA STATE BUILDING CODE
2018 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL RESIDENTIAL CODE
2018 INTERNATIONAL FIRE CODE
2018 INTERNATIONAL ENERGY CONSERVATION CODE
2018 INTERNATIONAL EXISTING BUILDING CODE
2018 INTERNATIONAL FUEL GAS CODE
2018 INTERNATIONAL MECHANICAL CODE
2018 INTERNATIONAL PLUMBING CODE
2017 NATIONAL ELECTRICAL CODE
- IEBC Accepted
- 1
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- None
- Structural Calculations Required
- No
Fire setbacks
- Fire Setback Enforced
- 1
Structural & loads
- Wind Speed
- 109
- Wind Notes
https://ascehazardtool.org/
- Snow Load
- 57
- Snow Load Notes
https://ascehazardtool.org/
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- AC Disconnect Required
- No
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,PV Breaker,Load Side Taps,Meter Adapter
- Supply Tap Neutral Ground Bond Required
- 1
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
- BOS Restrictions
Standard
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard ESS Requirements
- Separate ESS Disconnect Required
- No
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Standard
- Cover Page
Standard
- Site
Standard
- Roof Plan
Standard
- Electrical Diagram
Standard
- Label Page
Standard
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes
Minimum lot size: In the R-4, urban residential zoning district, a minimum lot size of 8,000 square feet is required.
Height: Ground-mounted solar energy systems shall not exceed 15 feet in height.
Location: In residential zoning districts, ground-mounted solar energy systems are limited to the rear yard. In nonresidential zoning districts, ground-mounted solar energy systems may be permitted in the front yard of any lot or the side yards on corner lots but shall not encroach in the minimum 20-foot landscaped area adjacent to public rights-of-way.
Setbacks: Ground-mounted solar energy systems, including any appurtenant equipment, shall be set back a minimum of 15 feet from all property lines and a minimum of 30 feet from all dwellings located on adjacent lots.
*Any deviation from the required standards of the Ordinance may be permitted through an Interim Conditional Use Permit
Solar Ordinance: Sec. 24-406. - Solar energy systems
- Setback Front Yard
- 15
- Setback Back Yard
- 15
- Setback Side Yard
- 15