City of Overland (MO)
NEC Code Version2017
Fire Code Version2018 Building Code
Wet Stamps RequiredDigital Structural
Fire Setback Enforced1
Codes
- NEC Code Version
- 2017
- Fire Code Version
- 2018 Building Code
- Code List
2018 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL RESIDENTIAL CODE
2018 INTERNATIONAL FIRE CODE
2018 INTERNATIONAL ENERGY CONSERVATION CODE
2018 INTERNATIONAL EXISTING BUILDING CODE
2018 INTERNATIONAL FUEL GAS CODE
2018 INTERNATIONAL MECHANICAL CODE
2018 INTERNATIONAL PLUMBING CODE
2017 NATIONAL ELECTRICAL CODE
- IEBC Accepted
- 1
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Date Plans are Stamped
Fire setbacks
- Fire Setback Enforced
- 1
Structural & loads
- Wind Speed
- 115
- Wind Notes
https://ascehazardtool.org/
Wind speed is 115mph or 89 with allowable stress design
- Snow Load
- 20
- Snow Load Notes
https://ascehazardtool.org/
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- AC Disconnect Required
- No
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,PV Breaker,Meter Adapter,Line Side Taps
- Supply Tap Neutral Ground Bond Required
- 1
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
- BOS Restrictions
Standard
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard ESS Requirements
- Separate ESS Disconnect Required
- No
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
- Provide specs showing inverts are in accordance with UL 1741
- Provide specs showing mods and racking are in accordance with UL 1703
- Cover Page
Standard
- Site
- Note the names of street(s) that adjoin the lot, the lot number, and the subdivision name
- Roof Plan
- Dimension the roof length and width
- Show the dimensions of the array(s). Add dimensions from edges of array(s) to roof edges and to other arrays
- Attachment Detail
Standard
- Electrical Diagram
Standard
- Label Page
Standard
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes
- Note the names of street(s) that adjoin the lot, the lot number, and the subdivision name
- Label all existing features/structures on the lot including septic and wells.
- Dimension an area free of brush that extends a minimum of 10ft from each side of the array
- Show with arrows water run off direction(s) and show and label existing swales. The location (s) of the solar PV array system structure shall not obstruct swales or run-off
- Show, label, and dimension pier locations and their on center spacing. Show and note pier and pier flare diameters and their required depth below grade
- Setback Front Yard
- 10
- Setback Back Yard
- 5
- Setback Side Yard
- 5