County of Dona Ana (NM)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2021 INTERNATIONAL RESIDENTIAL CODE
2021INTERNATIONAL EXISTING BUILDING CODE
2020 NATIONAL ELECTRICAL CODE
2021 UNIFORM MECHANICAL CODE
2021 UNIFORM PLUMBING CODE
2021 INTERNATIONAL FIRE CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
NMAC Title 14 - HOUSING AND CONSTRUCTION
2021 New Mexico Residential Building Code 14.7.3
2021 New Mexico Existing Building Code 14.7.7
2021 New Mexico Residential Energy Conservation Code 14.7.6
2021 New Mexico Plumbing Code 14.8.2
2021 New Mexico Mechanical Code 14.9.2
2020 New Mexico Electrical Code 14.10.4
2024 CFR PART 3280 BUILDING CODES - MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS  AS ADOPTED BY STATE OF NEW MEXICO - MANUFACTURED HOUSING (CID) (IF APPLICABLE)
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 1
- Revision Required
- 1
- Rough Inspection
- Footing inspection
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
MFG Homes require different setbacks. 36 inches on 3 sides of each unit of the home. 36 inches from ridge cap not to over lap the ridge
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 5
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
PE Requrements; SE & EE digital stamps on all PV pages, PE Letter & Calcs.
- Minimum Ground On Roof
- #10
Electrical
- AC Disconnect Required
- Yes
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Meter Adapter,Line Side Taps,Load Side Taps,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
PM and AC disco has be within 5 ft of the UM and add an additional disco on the exterior of the home LST is allowed in this AHJ. If main panel is inside and we are doing a LST we will need to a means of disconnect before our fusible AC disco. Also, service drop crossing a permanent structure is not allowed and will have to be relocated
- Custom Placards Required
- 1
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Ground Mount Notes
GM Array should be 50ft away from the road in front of the property