City of Henderson (NV)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2024 INTERNATIONAL BUILDING CODE
2024 INTERNATIONAL EXISTING BUILDING CODE
2024 INTERNATIONAL RESIDENTIAL CODE
2024 INTERNATIONAL FIRE CODE
2024 INTERNATIONAL WILDLAND-URBAN INTERFACE CODE
2024 UNIFORM MECHANICAL CODE
2024 UNIFORM PLUMBING CODE
2024 INTERNATIONAL SWIMMING POOL AND SPA CODE
2024 INTERNATIONAL ENERGY CONSERVATION CODE
2023 NATIONAL ELECTRICAL CODE
- IEBC Accepted
- 1
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Not accepted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 1
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Electrical,Digital Structural
- Structural Calculations Required
- Yes
- Ee Stamp Notes
PE Instructions
SE / EE digital stamps on all PV pages 1-7a, digitally stamped PE Letter & Calcs. PE Stamps need to have verifiable PDF valid digital signatures. Deliver stamped documents that are unlocked to allow for AHJ markup and digital stamp.
SE and EE stamps and digital Signature must show meta data next to stamp.
Digitally Verified Signature required.
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Snow Load Notes
N/A
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
ALL ENGINEERED DRAWINGS NEED TO HAVE DIGITAL SIGNATURES
PE Instructions
SE / EE digital stamps on all PV pages 1-7a, digitally stamped PE Letter & Calcs. PE Stamps need to have verifiable PDF valid digital signatures. Deliver stamped documents that are unlocked to allow for AHJ markup and digital stamp.
SE and EE stamps and digital Signature must show meta data next to stamp.
Digitally Verified Signature required.
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- All Jobs
- Allowed POI
- Meter Adapter,PV Breaker,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.87
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Batteries are not allowed on South or West walls due to the extreme summer heat.
When Battery needs to be installed in garage. Garage placement requirements:
- No matter where the battery is in the garage, it needs bollards.
- Bollards only need to be 6" away from battery instead of previous guidelines of 3ft
- Only 2 bollards are needed on leading edge.
- Bollard is not needed Infront of inverter
Heat and smoke detectors are required.
Relocate battery meter socket & disconnect switch to the battery branch leg of the PV circuit with battery socket closest to the batt storage unit. There shall be no meter socket/disc switch at where the backup panel is located (AC coupled system). Batt > PM > Disco > Combiner
- Separate ESS Disconnect Required
- Local Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
ALL JOBS
- 8x10 minimum photos showing the roof(s) where the modules are to be located
- An 8x10 minimum photo of the MSP or Sub panel that we are going to be landing our PV breaker in and a photo of the main breaker, also photo of the Panel Specs. Photos must show the panel open with the dead front off and a clear view of all the breakers present.
- Photos have to be high resolution and specs should be clearly readable.
- Spec sheet required for any sub panel, MPU, load center, etc.
- Electrical Load Calcs for all projects
- Flatten plans /remove PDF layers
BATTERY (Batteries mounted in garage)
- Provide floor plan with all code compliant information for power walls.
- Floor plan must include the lighting with switch locations
PRODUCTION HOMES NEW BUILT
***NEW CONSTRUCTION & OWNER AUTHORIZATION FORM NOT REQUIRED***
- Cover Page Notes
PRODUCTION HOMES NEW BUILT
***NEW CONSTRUCTION & OWNER AUTHORIZATION FORM NOT REQUIRED***
- Site
- If project has existing solar thermal panels, show location on plans
- Site Notes
PRODUCTION HOMES NEW BUILT
***NEW CONSTRUCTION & OWNER AUTHORIZATION FORM NOT REQUIRED***
- Electrical Diagram
LOAD CALCS FOR EVERY PROJECT
AHJ requires SLD & THREE LINE
Line side Tap are allowed on UL listed Solar ready MSP only, (with Square D Solar Ready MSP, we have to use "Current Limiters at the point of the line side tap in conjunction with the Square D tap kit (see attached spec sheets "Square D Solar Ready Tap Kit-CP Current limiting protectors")
PV breaker required to be at opposite end of busbar
Centerfed 120% allowed
- Label Page
- If project has an existing system both (E) and (N) systems should be shown on placard
- Add installer info label
- Custom Placards Required
- 1
- Placards Notes
make sure 2017 NEC rapid shutdown labels are installed.
- Non Standard Planset Requirements
- Single Line Diagram
- Non Standard Revision Requirements
REVISIONS: Please RED cloud and Delta any changes made to the plans and provide the revision letter of the changes made.
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Ground Mount Notes
- Propose a raceway/enclosure for the PV conductors, OR provide a fence detail to guard the perimeter of the array. If the fence is metallic and is within 6 ft. of the PV array, bond the fence every 50 ft. and include details/notes on the specific equipment used to bond the fence.
- For ground mounted PV arrays or PV arrays on detached structures, in addition to the equipment grounding conductor run with the PV system conductors, a grounding conductor shall be provided from the PV array to a grounding electrode system established at that ground mount or detached structure.