Village of Lynbrook (NY)
Codes
- NEC Code Version
- 2023
- Code List
2025 NEW YORK STATE BUILDING CODE
2025 NEW YORK STATE RESIDENTIAL CODE
2025 NEW YORK STATE FIRE CODE
2025 NEW YORK STATE ENERGY CONSERVATION CODE
2025 NEW YORK STATE EXISTING BUILDING CODE
2025 NEW YORK STATE FUEL GAS CODE
2025 NEW YORK STATE MECHANICAL CODE
2025 NEW YORK STATE PLUMBING CODE
2025 NEW YORK STATE ENERGY STANDARD FOR SITES AND BUILDINGS EXCEPT LOW-RISE RESIDENTIAL BUILDINGS
2023 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 2
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 0
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 85
- Snow Load
- 999
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- Allowed POI
- PV Breaker,Line Side Taps,Meter Adapter,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Plans must include color renderings of the panels superimposed on the home - along with color pictures of the front/side/rear of home. Conduit location to be shown in dark color on renderings. Specify that the panels cannot be seen from the street. Conduit must be shown in different colors for roof jumpers and DC conduit to inverter. (Blue for DC roof pipe, yellow for DC homerun to INV)
- Site
Conduit will need to be show on the site plan.
- Roof Plan
Panels may not be placed on either the front of house or where they can be seen from the street, unless there is an exception (i.e. house on dead-end street surrounded by commercial buildings).
- Attachment Detail
Please be advised this AHJ requires a mandatory architectural review board meeting ; panel placement is very important. With that, please try to avoid the front facing roof of home, especially if they can be seen from street. If corner house be mindful of the two sides of roof that face the street ; same applies to avoid panels being visible from street. Highly unlikely any project where panels are visible from street, especially on front, will be approved for permit.
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim