City of Eugene (OR)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2022 OREGON STRUCTURAL SPECIALTY CODE
2023 OREGON RESIDENTIAL SPECIALTY CODE
2023 OREGON ELECTRICAL SPECIALTY CODE
2025 OREGON ENERGY EFFICIENCY SPECIALTY CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- Other (See Submission Notes)
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 1
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- None
- Structural Calculations Required
- No
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Please Complete the Oregon Fire Setback Checklist before you complete your aurora design.
All solar roof planes MUST have 36โ pathways along 3 sides of the roof plane. Pathways cannot be over unsupported areas like overhangs and eaves - Pathways must start from the load bearing wall. The following exceptions below allow us to avoid having 3 pathways on each plane:
- Total array area is not greater than 1,000 sqft and it has an intersecting adjacent roof plane free of solar panels.
- If #1 applies AND total array area does not exceed 25% of roof area that the array is on, then one 12โ pathway is required along each side of the horizontal ridge.
- If #1 applies AND the total array area exceeds 25% of total roof area that the array is on, then one 12โ pathway is required song each side of the horizontal ridge AND one 36โ pathway from ridge to eave shall be provided.
Pathways are not required on non-occupied accessory structures, provided that they are separated from occupied structures by not less than 60 inches or by a minimum two-hour fire-rated assembly. When using this exception, please include a dimension of the shortest distance between the array building and the nearest occupied structure.
Pathways are not allowed within 12" of low point valleys.
Pathways cannot straddle ridges/hips
Additional information and examples of acceptable fire setbacks can be found in the files below.
Structural & loads
- Wind Speed
- 999
- Snow Load
- 15
- Snow Load Notes
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 48
- Structural Notes
- Stamps/calcs not needed per Permit Coordinator
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Line Side Taps,Meter Adapter,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
#NFZ_ALL#
- Roof Plan
Must show rafters/trusses as well as connection points
Must show dimensions of roof array (See "Dimensions Example" in Files)
Must show unsupported Span
- Attachment Detail
Attachments shall be spaced not greater than 24 inches (609.6 mm) on center in any direction where:
- Ground snow [loads] exceed 36 psf (1.197 kN/m2).
- Located within 3 feet (914 mm) of a roof edge, hip, eave or ridge.
- Located in wind Exposure Category B or greater and the wind speed exceeds 120 mph.
- Located in wind Exposure Category C or greater and the wind speed exceeds 110 mph.
- Custom Placards Required
- 1
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Ground Mount Notes
Site plan to include overall dimensions of the solar array