County of Lincoln (OR)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2023 OREGON RESIDENTIAL SPECIALTY CODE
2022 OREGON STRUCTURAL SPECIALTY CODE
2022 OREGON MECHANICAL SPECIALTY CODE
2023 OREGON PLUMBING SPECIALTY CODE
2025 OREGON ENERGY EFFICIENCY SPECIALTY CODE
2019 OREGON ZERO ENERGY READY COMMERCIAL CODE
2019 OREGON FIRE CODE
2010 OREGON MANUFACTURED DWELLING INSTALLATION SPECIALTY CODE
2023 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
All photovoltaic installations shall include a 36-inch wide (914 mm) pathway maintained along three sides of the solar roof. The bottom edge of a roof with a slope exceeding two units vertical in 12 units horizontal (2:12) shall not be used as a pathway. All pathways shall be located over a structurally supported area and measured from the edge of the roof and horizontal ridge to the solar array or any portion thereof.
Exceptions :
- Structures with a photovoltaic array area of 1,000 square feet (92.90 m2) or less installed on a roof with a slope exceeding two units vertical in 12 units horizontal (2:12) with an intersecting adjacent roof and where no section is larger than 150 feet (45720 mm) measured in length or width: 1. Where the photovoltaic array does not exceed 25 percent, as measured in plan view, of total roof area of the structure, a minimum 12-inch (305 mm) unobstructed pathway shall be maintained along each side of any horizontal ridge. 2. Where the solar array area exceeds 25 percent, as measured in plan view, of total roof area of the structure, a minimum of one 36-inch (914 mm) unobstructed pathway from ridge to eave, over a structurally supported area, must be provided in addition to a minimum 12-inch (305 mm) unobstructed pathway along each side of any horizontal ridge.
- Pathways are not required on nonoccupied accessory structures provided that they are separated from occupied structures by a 6-foot (3048 mm) minimum separation distance or by a minimum two-hour fire-rated assembly.
- Townhouses providing fire separation as required by the applicable code at the time of construction may be considered one structure and comply with the provisions of Section 3111.3.4.8.1, Exception 1.1.
3111.3.4.8.2 Intermediate Pathway Locations
Systems that include a solar array section that is larger than 150 feet (45720 mm) measured in length or width shall have additional intermediate pathways. An intermediate pathway not less than 36 inches (914 mm) wide separating the array , shall be provided for every 150 feet (45720 mm) of array, including offset modules or angled installations. The maximum square footage of an array shall not exceed 22,500 square feet (2092 m2) without the installation of an intermediate pathway.
3111.3.4.8.2.1 Where Required
Where a system is required to have intermediate pathways , all pathways shall have one or more cutouts located adjacent to the pathway. No point on the pathway shall be more than 25 feet (7620) from a cutout.
Structural & loads
- Wind Speed
- 120
- Snow Load
- 36
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 48
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Line Side Taps,Meter Adapter,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
- Attachment Detail
Attachments shall not be spaced greater than 24 inches (609.6 mm) on center in any direction where:
- Ground snow loads exceed 36 psf (1.197 kN/m2).
- Located within 3 feet (914 mm) of a roof edge, hip, eave or ridge.
- Located in wind Exposure Category B or greater and the wind speed exceeds 120 mph.
- Located in wind Exposure Category C or greater and the wind speed exceeds 110 mph.
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim