County of Marion (OR)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- N/A
- Code List
2021 STATE OF OREGON RESIDENTIAL SPECIALTY CODE
2022 STATE OF OREGON STRUCTURAL SPECIALTY CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2019 STATE OF OREGON MECHANICAL SPECIALTY CODE
2021 STATE OF OREGON PLUMBING SPECIALTY CODE
2023 STATE OF OREGON ELECRTICAL SPECIALTY CODE
2023 NATIONAL ELECTRICAL CODE
2025 OREGON ENERGY EFFICIENCY SPECIALTY CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- Other (See Submission Notes)
- Revision Required
- 1
- New Planset Required For Module Swap
- 1
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- None
- Structural Calculations Required
- No
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
All PV installs shall include a 36" wide pathway maintained along (3) sides of the solar roof. The bottom edge of a roof cannot be used as a pathway. ....Where the solar array area exceeds 25% of total roof area, one 36in pathway from ridge to eave must be provided...
Structural & loads
- Wind Speed
- 100
- Snow Load
- 25
- Snow Load Notes
Ground snow load: 25 PSF
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 48
- Structural Notes
- If the project meets the minimum requirements listed on the Oregon Prescriptive Solar Checklist, no stamps or structural documents will be required. If the project does not meet the minimum requirements listed on the Oregon Prescriptive Solar Checklist, we will NEED stamps and supporting structural documents for permit submission. Summary of checklist: Attachments must be spaced not greater than 48 inches (1219 mm) on center in any direction. Attachments shall be spaced not greater than 24 inches (609.6 mm) on center in any direction where: 1. Ground snow loads exceed 36 psf (1.197 kN/m2). 2. Located within 3 feet (914 mm) of a roof edge, hip, eave or ridge. 3. Located in wind Exposure Category B or greater and the wind speed exceeds 120 mph. 4. Located in wind Exposure Category C or greater and the wind speed exceeds 110 mph.
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,Meter Adapter,PV Breaker,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
AHJ Requirements - Structural
any manufactured homes(with2x2 truss), flat roof, tiled roofs, metal framing, or pole buildings we cannot apply prescriptively. These all require Structural Stamps, PE Letter, and Calcs
Please obtain the following when designing on any manufactured homes(with2x2 truss), flat roof, tiled roofs, metal framing, or pole buildings
-Stamps on plans
-PE Letter
-structural calcs
- Site
- Site Notes
All Jobs [All PV installs shall include a 36" wide pathway maintained along (3) sides of the solar roof. The bottom edge of a roof cannot be used as a pathway. .... Where the solar array area exceeds 25% of total roof area, one 36in pathway from ridge to eave must be provided...]
- Attachment Detail
Attachments shall not be spaced greater than 24" where Ground Snow load exceed 36 psf, located within 3 feet of a roof edge, hip, eave or ridge. Located in wind Exposure Category B or greater and the wind speed exceeds 120 mph. Located in wind Exposure Category C or greater and the wind speed exceeds 110 mph.
- Attachment Detail Notes
Roof Mount [The attachments shall be spaced not more than 24 inches on center in any direction where the attachments are located within 3 ft of a roof edge, hip, eave, or ridge.]
- Custom Placards Required
- 0
- Non Standard Revision Requirements
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes