City of East Providence (RI)
NEC Code Version2017
Fire Code Version2018 Building Code
Wet Stamps RequiredDigital Structural,Digital Electrical
Fire Setback Enforced1
Codes
- NEC Code Version
- 2017
- Fire Code Version
- 2018 Building Code
- Code List
2019 RHODE ISLAND BUILDING CODE 2019 RHODE ISLAND RESIDENTIAL CODE 2019 RHODE ISLAND FIRE CODE 2019 RHODE ISLAND PLUMBING CODE 2019 RHODE ISLAND MECHANICAL CODE 2019 RHODE ISLAND ENERGY CODE 2019 RHODE ISLAND ADMINISTRATIVE CODE 2019 RHODE ISLAND ELECTRICAL CODE
- IEBC Accepted
- 1
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 1
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Ee Stamp Notes
SE / EE digital stamps on all PV pages 1-7a & PE Letters / Calcs.
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Fire Setbacks enforced per Rhode Island Fire Code and NFPA - 1
Structural & loads
- Wind Speed
- 130
- Wind Notes
Exposure Category C. Wind-borne debris region.
- Snow Load
- 30
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
PE Requirements; SE / EE digital stamps on all PV pages & PE Letter / Calcs. WS 130 MPH GSL 30
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,Load Side Taps,PV Breaker,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 1
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Master Plan Set combining all individual projects into one plan set showing all panels/systems/etc if a project has multi-system job
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim