City of Woonsocket (RI)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2019 RHODE ISLAND BUILDING CODE
2019 RHODE ISLAND RESIDENTIAL CODE
2019 RHODE ISLAND FIRE CODE
2019 RHODE ISLAND PLUMBING CODE
2019 RHODE ISLAND MECHANICAL CODE
2019 RHODE ISLAND ENERGY CODE
2019 RHODE ISLAND ADMINISTRATIVE CODE
2019 RHODE ISLAND ELECTRICAL CODE
2020 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- Other (See Submission Notes)
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Ee Stamp Notes
EE stamp required on ALL electrical pages, INCLUDING placards pages
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 130
- Wind Notes
Exposure Category B
- Snow Load
- 40
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
When installing multiple projects on a home, there will need to be a master plan set and master PE letter/calcs showing both systems together in addition to the individual plans + supporting docs for the separate projects.
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Line Side Taps,Load Side Taps,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 1
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
When installing multiple projects on a home, there will need to be a master plan set and master PE letter/calcs showing both systems together in addition to the individual plans + supporting docs for the separate projects.
- Label Page
- Stickers page MUST match SLD and site conditions. Example, if there is no production meter, we cannot show a PM on the sticker page.
- Additionally, numbers on the sticker page must match the numbers from the backfeed sizing section on the SLD. Please see example below in attachments "Approved Planset" for reference.
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim