City of Bellaire (TX)
Codes
- NEC Code Version
- 2017
- Fire Code Version
- 2018 Building Code
- Code List
2018 International Building Code 2018 International Residential Code 2018 International Mechanical Code 2018 International Plumbing Code 2018 International Fuel Gas Code 2018 International Fire Code 2018 International Energy Conservation Code 2018 International Swimming Pool, Spa Code 2017 National Electrical Code
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
For each roof plane with a PV array, a pathway of not less than 36 inches wide shall be provided from the lowest roof edge to the ridge on the same roof plane as the photovoltaic array, on an adjacent roof plane, or straddling the same and adjacent roof planes.
Structural & loads
- Wind Speed
- 136
- Wind Notes
Exposure Category C
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- All Jobs
- Allowed POI
- PV Breaker,Meter Adapter,Line Side Taps,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 75
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Electrical Diagram
If MPU is being performed, must show Service conductors from the overhead feed are rated for 200A (3/0 AWG Hots/Neutral; 4 AWG Ground; 2-1/2" EMT)
- Non Standard Planset Requirements
- BOS Elevation
- Non Standard Revision Requirements
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim