City of Bells (TX)
Spot something wrong?
These change with code cycles. If a requirement here is out of date or missing, tell us and we'll fix it.
Report a correction NEC Code Version2020
Fire Code Version2018 Building Code
Wet Stamps RequiredDigital Structural
Fire Setback EnforcedYes
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
- BUILDING CODES A permit is required prior to the commencement of any construction located on property within the City limits. Activities requiring permits are listed below: 2012 International Building Code 2012 International Residential Code for One and Two-Family Dwellings 2012 International Mechanical Code 2012 International Plumbing Code 2012 International Fire Code 2012 International Fuel Gas Code 2012 International Energy Conservation Code 2012 International Property Maintenance Code 2011 National Electrical Code (with local amendments) These codes can be purchased in their entirety through the International Code Council.
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- No
- New Planset Required For Module Swap
- No
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- Yes
- Setback Notes
- Standard
Structural & loads
- Wind Speed
- 90
- Snow Load
- 5
- Reducible Snow Load Allowed
- Yes
- Minimum Ground On Roof
- #10
Electrical
- Allowed POI
- Load Side Taps,Line Side Taps,PV Breaker,Meter Adapter
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- No
- ESS Notes
- Standard
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim