City of Elgin (TX)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2021 INTERNATIONAL RESIDENTIAL CODE 2021 INTERNATIONAL BUILDING CODE 2021 INTERNATIONAL PLUMBING CODE 2021 INTERNATIONAL SWIMMING POOL CODE 2021 INTERNATIONAL FUEL GAS CODE 2021 INTERNATIONAL MECHANICAL CODE 2020 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 5
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Meter Adapter,PV Breaker,Line Side Taps,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- No
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
P. Type of roof covering, number of roofing layers and age of roof. If existing roof is nearing the end of normal life expectancy, a reroof may be prudent prior to installing rooftop photovoltaics. Q. Type of roof framing (i.e. conventional or truss), size and spacing of roof framing members. R. Weight of modules, support locations, method of attachment and wind load design. S. Framing plan and any details relative for any work necessary to reinforce existing roof for additional loads to be imposed.
- Roof Plan
P. Type of roof covering, number of roofing layers and age of roof. If existing roof is nearing the end of normal life expectancy, a re‐roof may be prudent prior to installing rooftop photovoltaics. Q. Type of roof framing (i.e. conventional or truss), size and spacing of roof framing members. R. Weight of modules, support locations, method of attachment and wind load design. S. Framing plan and any details relative for any work necessary to reinforce existing roof for additional loads to be imposed.
- Label Page
Specify that labeling of all equipment to comply with Articles 690 & 705 of the 2014 National Electrical Code (NEC).
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- No