City of Katy (TX)

Texas Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2023
Fire Code Version2018 Building Code
Wet Stamps RequiredDigital Structural
Fire Setback Enforced1

Codes

NEC Code Version
2023
Fire Code Version
2018 Building Code
Code List

2021 INTERNATIONAL BUILDING CODE

2021 INTERNATIONAL ENERGY CONSERVATION CODE

2021 INTERNATIONAL EXISTING BUILDING CODE

2021 INTERNATIONAL FIRE CODE

2021 INTERNATIONAL FUEL AND GAS CODE

2021 INTERNATIONAL MECHANICAL CODE

2021 INTERNATIONAL PLUMBING CODE

2021 INTERNATIONAL PROPERTY MAINTENANCE CODE

2021 INTERNATIONAL RESIDENTIAL CODE

2021 INTERNATIONAL SWIMMING POOL AND SPA CODE

2021 NFPA 101 LIFE SAFETY CODE

2023 NATIONAL ELECTRICAL CODE

ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

How Many Plansets Required
2
Revision Required
1
New Planset Required For Module Swap
0

Stamps

Wet Stamps Required
Digital Structural
Structural Calculations Required
Yes
Stamp Location On Plans
Unspecified
Date On Stamps
Expiration Date

Fire setbacks

Fire Setback Enforced
1
Setback Notes

Standard

Structural & loads

Wind Speed
136
Wind Notes

Exposure Category C

Snow Load
0
Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Structural Notes

structural calcs must include 2015 IRC SE digital stamps on corresponding PV pages & PE Letter / Calcs. WS: 136mph. Exposure Category C. The structural calcs must specifically state "The roof of the home will support the loads of all PV panels" If there is an existing system on the home, the PE letter/calcs must certify that the roof can withstand the addition of both the existing solar and the new solar panels being installed.

Minimum Ground On Roof
#10

Electrical

Electrical Load Calcs Required
Derates
Allowed POI
Line Side Taps,Load Side Taps,PV Breaker,Meter Adapter
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
0.96

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes

Standard

Separate ESS Disconnect Required
No
ESS Elevation Detail Required
No

Plan set

Electrical Diagram

Standard

Label Page

We cannot have labels on the plans that will not be installed on site. Please reference the file "remove these labels" below and delete any label from the plans that is marked with "N" on that picture. The relay template will be updated to remove these automatically for future projects.

Custom Placards Required
0
Placards Notes
The city of Katy itself does not require placards for their inspections. HOWEVER if a katy job resides in Centerpoint jurisdiction then we will need placard for Centerpoint. AG

Ground mount

Ground Mount Fencing Required
No
Ground Mount Notes

Ground screws are allowed with SE stamp. 2018 IFC Setback Requirements

Compiled from public records, 2026. Requirements change with code cycles and local amendments. Verify with the City of Katy (TX) building department before you rely on this, and treat it as a research head start, not a ruling. Getting quotes? Run them through the quote checker first.