City of Kennedale (TX)
NEC Code Version2017
Fire Code Version2018 Building Code
Wet Stamps RequiredDigital Structural,Digital Electrical
Fire Setback Enforced1
Codes
- NEC Code Version
- 2017
- Fire Code Version
- 2018 Building Code
- Code List
- 2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL RESIDENTIAL CODE 2018 INTERNATIONAL MECHANICAL CODE 2018 INTERNATIONAL PLUMBING CODE 2018 INTERNATIONAL FUEL GAS CODE 2018 INTERNATIONAL FIRE CODE 2018 INTERNATIONAL ENERGY CONSERVATION CODE 2018 INTERNATIONAL EXISTING BUILDING CODE 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE 2017 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 2
- Revision Required
- 1
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
- Standard
Structural & loads
- Wind Speed
- 90
- Wind Notes
Also, note needed compliance with local wind loading requirements: 90 MPH (3-second-gust/75 fastest mile)
- Snow Load
- 5
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
- Letter from a Texas Licensed Professional Engineer including the following: * A statement that the roof of the structure is adequate to support the proposed panels * Any recommended modifications to the roof along panel support and bracing systems
- Minimum Ground On Roof
- #10
Electrical
- AC Disconnect Required
- Yes
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Meter Adapter,Load Side Taps,PV Breaker,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
- Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Roof Plan
- * Scaled, dimensioned, LABELED plans * Site plan (to scale) showing the location of major components on the property
- Roof Plan Notes
- 90 MPH (3-second-gust/75 fastest mile)
- Attachment Detail
- * A roof plan, side elevations of collectors, and mounting details. * Weight of the arrays (pounds per square foot- including mounting hardware) * Describe and show the roof structural elements, including * Rafter size, span, and spacing * Roof sheathing * Additional structural calculations and/or engineer’s verification of load capacity of the roof structure * Roofing type (e.g. composition shingle, shake, light-weight tile, etc.) and pitch * Details of PV panel mounting hardware attachment to the roof framing member
- Electrical Diagram
- Electrical line diagram of the electrical equipment (including make, model, and size of units) prepared by a Texas Licensed Professional Engineer of the PV array configuration showing: wiring system, overcurrent protection, grounding, inverter, disconnects, required signs, AC connection to building, and size and location of electrical panel
- Label Page
- A labeled, itemized list of solar collectors and other system components approved by a national recognized agency, including data specification sheet for PV system and components
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim