City of Kennedale (TX)

Texas Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2017
Fire Code Version2018 Building Code
Wet Stamps RequiredDigital Structural,Digital Electrical
Fire Setback Enforced1

Codes

NEC Code Version
2017
Fire Code Version
2018 Building Code
Code List
2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL RESIDENTIAL CODE 2018 INTERNATIONAL MECHANICAL CODE 2018 INTERNATIONAL PLUMBING CODE 2018 INTERNATIONAL FUEL GAS CODE 2018 INTERNATIONAL FIRE CODE 2018 INTERNATIONAL ENERGY CONSERVATION CODE 2018 INTERNATIONAL EXISTING BUILDING CODE 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE 2017 NATIONAL ELECTRICAL CODE
ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

How Many Plansets Required
2
Revision Required
1
New Planset Required For Module Swap
0

Stamps

Ee Stamp Required On SLD
Yes
Wet Stamps Required
Digital Structural,Digital Electrical
Structural Calculations Required
Yes
Stamp Location On Plans
Unspecified
Date On Stamps
Expiration Date

Fire setbacks

Fire Setback Enforced
1
Setback Notes
Standard

Structural & loads

Wind Speed
90
Wind Notes

Also, note needed compliance with local wind loading requirements: 90 MPH (3-second-gust/75 fastest mile)

Snow Load
5
Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Structural Notes
Letter from a Texas Licensed Professional Engineer including the following: * A statement that the roof of the structure is adequate to support the proposed panels * Any recommended modifications to the roof along panel support and bracing systems
Minimum Ground On Roof
#10

Electrical

AC Disconnect Required
Yes
Electrical Load Calcs Required
Derates
Allowed POI
Meter Adapter,Load Side Taps,PV Breaker,Line Side Taps
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
0.91

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes
Standard
Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Plan set

Roof Plan
* Scaled, dimensioned, LABELED plans * Site plan (to scale) showing the location of major components on the property
Roof Plan Notes
90 MPH (3-second-gust/75 fastest mile)
Attachment Detail
* A roof plan, side elevations of collectors, and mounting details. * Weight of the arrays (pounds per square foot- including mounting hardware) * Describe and show the roof structural elements, including * Rafter size, span, and spacing * Roof sheathing * Additional structural calculations and/or engineer’s verification of load capacity of the roof structure * Roofing type (e.g. composition shingle, shake, light-weight tile, etc.) and pitch * Details of PV panel mounting hardware attachment to the roof framing member
Electrical Diagram
Electrical line diagram of the electrical equipment (including make, model, and size of units) prepared by a Texas Licensed Professional Engineer of the PV array configuration showing: wiring system, overcurrent protection, grounding, inverter, disconnects, required signs, AC connection to building, and size and location of electrical panel
Label Page
A labeled, itemized list of solar collectors and other system components approved by a national recognized agency, including data specification sheet for PV system and components
Custom Placards Required
0

Ground mount

Ground Mount Fencing Required
Mesh/Scrim
Compiled from public records, 2026. Requirements change with code cycles and local amendments. Verify with the City of Kennedale (TX) building department before you rely on this, and treat it as a research head start, not a ruling. Getting quotes? Run them through the quote checker first.