City of Pflugerville (TX)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2021 INTERNATIONAL BUILDING CODE 2021 INTERNATIONAL RESIDENTIAL CODE 2021 INTERNATIONAL PLUMBING CODE 2021 INTERNATIONAL MECHANICAL CODE 2021 INTERNATIONAL CODE COUNCIL ELECTRICAL CODE 2021 INTERNATIONAL FUEL GAS CODE 2021 INTERNATIONAL ENERGY CONSERVATION CODE 2021 INTERNATIONAL FIRE CODE 2021 INTERNATIONAL EXISTING BUILDING CODE 2021 INTERNATIONAL PROPERTY MAINTENANCE CODE 2020 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- Other (See Submission Notes)
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 1
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 5
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Meter Adapter,Load Side Taps,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Service Ground Requirements
- Temperature Rating
- 75
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Make note on line diagram if battery is exterior or interior mounted
If Mounting interior, all the requirements in file titled ESS INTERIOR REQUIREMENTS must be satisfied
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
If using Enphase combined box, include spec sheet in plans.
Hot Bus is not allowed. We must have a main breaker within the MSP or an MBE upstream if there is Hot Bus MSP.
- Roof Plan
Please make sure that Make / model / type for inverters is also located on Site plan and roof plan.
- Electrical Diagram
AHJ enforces NEC 110.14 (C)(1) and will require us to EITHER: * Use 60C terminal ratings for wire sizing if circuit is under 100A * Use 75C terminal ratings for wire sizing if circuit is over 100A * Prove that equipment is listed and identified for use with higher terminal ratings (IE show that equipment terminal ratings are 75C or higher via cut sheets)
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- No