City of Schertz (TX)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2018 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL FIRE CODE
2018 INTERNATIONAL RESIDENTIAL CODE
2018 INTERNATIONAL FUEL & GAS CODE
2018 INTERNATIONAL MECHANICAL CODE
2018 INTERNATIONAL PLUMBING CODE
2018 INTERNATIONAL PROPERTY MAINTENANCE CODE
2015 INTERNATIONAL ENERGY CONSERVATION CODE
2023 NATIONAL ELECTRIC CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 1
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
33% rule to account for only roof plans with mods, if those roof plans higher apply the 3 ft at ridge
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category C
- Snow Load
- 5
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Requires structural observation letter including standard structural calcs WS 115 MPH SL 5 PSF
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Meter Adapter,Load Side Taps,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Floor plan / Garage plan is required with battery attachment details if ESS is installed inside the garage
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
SURGE PROTECTOR IS REQUIRED FOR ALL PROJECTS
- Custom Placards Required
- 1
- Placards Notes
Placard is required to be placed for inspection.
Open obtain placard task, prefill the task.
Mark it in TODO and assign the task to Zakery Arreola.
Leave this note in unified notes section.
Prepare Inspection
Action Taken: Opened obtain placard task.
Summary of items to complete before Final Inspection: 1 6x8 placard, (attached pdf of placard to note.)
Next Follow-Up Date: 2-3 days.
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim